airmaster TIGER 8/250 Operation & Maintenance Instructions Manual

airmaster TIGER 8/250 Operation & Maintenance Instructions Manual

24l air compressor

Advertisement

24L AIR COMPRESSOR
MODEL NO: TIGER 8/250
PART NO: 2244000
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS
LS0620 - ISS 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TIGER 8/250 and is the answer not in the manual?

Questions and answers

Summary of Contents for airmaster TIGER 8/250

  • Page 1 24L AIR COMPRESSOR MODEL NO: TIGER 8/250 PART NO: 2244000 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0620 - ISS 6...
  • Page 2: Environmental Recycling Policy

    INTRODUCTION Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Before using your compressor it is in your own interest to read and pay attention to the following safety rules. 1. Compressed air is dangerous. Do not point a jet of air at persons or animals, and do not discharge compressed air against the skin.
  • Page 4: Safety Symbols

    SAFETY SYMBOLS Read this instruction booklet carefully before positioning, operating or adjusting the compressor. Risk of electric shock. The compressor must be disconnected from the mains supply before removing any covers. Do not use in a damp environment. Risk of accidental start-up. The compressor could start automatically in the event of a power cut and subsequent reset.
  • Page 5: Electrical Connections

    ELECTRICAL CONNECTIONS WARNING! Read these electrical safety instructions thoroughly before connecting the product to the mains supply. Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch. If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions shown below.
  • Page 6: Attach The Wheels

    ASSEMBLY ATTACH THE WHEELS Use a spanner to attach the wheels to the compressor. Use the washers and spring washer in the positions shown. ATTACH THE SUPPORT FEET Insert the support feet into the position shown. FIT THE AIR FILTER 1.
  • Page 7: Fit The Oil Filler Cap

    FIT THE OIL FILLER CAP 1. Remove the travel plug. 2. Insert the oil filler cap. MOVING THE AIR COMPRESSOR CAUTION: TO PREVENT INJURY, GET ASSISTANCE WHEN LIFTING THIS COMPRESSOR. • Stop the compressor and disconnect it from the power supply before you move it.
  • Page 8: Before Use

    BEFORE USE Before connecting your compressor to the power supply, check the following:- • Set the ON/OFF switch to the OFF position (pushed down). • Make sure that the compressor is on level ground. • Make sure that the supply voltage matches the voltage shown on the data label.
  • Page 9: Operation

    OPERATION If the compressor has not been used for more then 24 hours, open the drain valve (on the bottom of the reservoir) and drain any condensate which has collected. See page 11 ATTACHING AIR TOOLS WARNING: BEFORE CONNECTING AIR TOOLS, MAKE SURE THAT YOU READ THE INSTRUCTIONS SUPPLIED WITH THE TOOL, ALSO ENSURE THAT THE TOOL IS SUITABLE FOR USE WITH THE COMPRESSOR AND HOSE SPECIFICATIONS.
  • Page 10: Set The Output Pressure

    SET THE OUTPUT PRESSURE When viewed from the front, the left hand outlet valve is adjustable. The right hand outlet valve will only supply the full reservoir pressure and is not adjustable. 1. Use the pressure regulator to set the output pressure of the left hand outlet valve.
  • Page 11: Turning The Compressor Off

    2. Turn the outlet valve handle to the off position. 3. Operate the tool to depressurise the air hose. 4. Disconnect the tool from the hose. TURNING THE COMPRESSOR OFF 1. Follow steps 1-3 in “Removing Tools From The Air Hose” above. 2.
  • Page 12: Reset Button

    RESET BUTTON This compressor has a thermal overload device. If the motor gets too hot, the thermal overload device cuts the power which prevents damage to the motor. If the thermal overload device operates, let the motor cool down for 5 minutes and push the reset button.
  • Page 13: Maintenance

    MAINTENANCE DRAIN THE RESERVOIR (DAILY) After use, always open the drain valve to make sure that any condensate is drained off. CLEAN THE AIR FILTER (MONTHLY) The air filter must be examined monthly, more often in dusty conditions, 1. Remove the filter cover from the compressor.
  • Page 14: Check The Non-Return Valve (Every 6 Months)

    CHECK THE NON-RETURN VALVE (EVERY 6 MONTHS) If the reservoir pressure decreases for no apparent reason, it is possible that the non-return valve is leaking. To check, 1. Make sure that the reservoir is not under pressure and the compressor is switched OFF. 2.
  • Page 15: Troubleshooting

    TROUBLESHOOTING CAUTION: DO NOT TRY TO REPAIR OR ADJUST THIS COMPRESSOR IF YOU ARE UNCERTAIN. IF YOU HAVE ANY QUERIES, CONTACT YOUR DEALER. PROBLEM PROBABLE CAUSE REMEDY The compressor Bad electrical connections. 1. Check electrical connections. has stopped and 2. Clean and tighten if necessary. does not start.
  • Page 16: Exploded Diagram

    EXPLODED DIAGRAM...
  • Page 17: Parts List

    PARTS LIST DESCRIPTION DESCRIPTION Motor Cover Bolt M8x105 Bolt M5x105 Cylinder Head Wind Leaf Air Filter Circlip Cylinder Seals Connector Valve Plate Fan Cover Valve Plate Gasket Nut M8 Valve Clack Flap Capacitance Cylinder Thermal Protector Cylinder Gasket Bolt M5x12 Gas Ring Nut M8 Oil Ring...
  • Page 18: Declaration Of Conformity

    DECLARATION OF CONFORMITY...
  • Page 19 DECLARATION OF CONFORMITY...