Compressor Reverse Rotation Protection Control; Dew Prevention Control - Panasonic CU-PC12JKF Service Manual

Hide thumbs Also See for CU-PC12JKF:
Table of Contents

Advertisement

• The current fan speed will change to freeze prevention speed after 70 seconds compressor on. The fan speed will be increased
according to the indoor pipe temperature the figure below.
• Restart control (Time Delay Safety Control) will be applied in this control if the recovery time is too short.

13.6. Compressor Reverse Rotation Protection Control

• If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor
heat exchanger is 2.5°C or less for continuous 2 minutes, compressor will stop and restart automatically.
• Time Delay Safety Control is activated before the compressor restart.
• This is to prevent compressor from rotate reversely when there is an instantaneous power failure.
• If this condition happens continuously for 5 times within 50 minutes, unit will turns OFF with TIMER indicator blinks.
• The 5 times counter can be reset when either one of the following condition happen:
- Unit is OFF by remote control or AUTO OFF/ON button.
- Indoor intake temperature - Indoor piping temperature >5°C for 1 minutes or more.
- Operation mode change.
• The unit could be ON by pressing OFF/ON button at remote control but the TIMER LED will continue blinking.
• TIMER LED blinking will be reset if:
- Indoor intake temperature - Indoor piping temperature >5°C for 1 minutes or more.
- Power supply reset.

13.7. Dew Prevention control

• To prevent dew formation at indoor unit discharge area.
• This control will be activated if:-
- Cooling mode.
- Remote Control setting temperature is less than 25°C.
- Fan speed is at CLo.
- Room temperature is constant (±1°C) for 60 minutes.
- Compressor is continuously running.
• Fan speed will be adjusted accordingly in this control.
- Fan speed will be increased slowly.
• Dew prevention stop condition
- Remote control setting temperature is more than 25°C.
- Fan speed is not set to CLo.
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-pc12jkf