Error Code Chart - Projecta SC420/ND Manual

Mppt solar charge controller
Table of Contents

Advertisement

8. Error Code Chart

CODE
Error
E00
No Error
Battery
E02
Over-voltage
Controller
E06
Over-temperature
Battery Sensor
E07
Over-temperature
E10
Solar Over-voltage
Solar Reverse
E13
Polarity
Battery Reverse
E14
Polarity
8.2 Battery Temperature Sensor:
As an option, the unit provides a port to connect the external battery temperature sensor. If it is used, the
unit will optimise the charging performance subjected to the battery temperature
Description
-
Battery output voltage has
exceeded the controller's max-
imum rating
Controller has exceeded the
ambient temperature limit
The surrounding temperature
around the temperature
sensor is too high
Solar input voltage has
exceeded the controller's max-
imum rating
Solar input cables are
connected in reverse
Battery output cables are
connected in reverse
Quick Troubleshoot
Check whether there is an external voltage applied
to the battery
Ensure the controller is placed
in a well-ventilated area.
Check the sensor is not near a hot source.
Battery may be faulty if it is too hot
Lower the solar panel's total voltage connected
to the controller
Disconnect and reconnect with the correct polarity
Disconnect and re-connect with
correct wire polarity
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc440/nd

Table of Contents