G2500/G2500 OPS
12. Troubleshooting Guide
Case 1. Starting failure
WARNING
• Make sure the icing prevention system is not working.
Check fuel for water
or substandard mix-
ture.
➡
C h e c k f o r e n g i n e
flooding.
➡
Check spark ignition.
13. Disposal
• When you dispose of the machine, do not disas-
semble the machine.
• When you dispose of the machine, fuel, chain oil,
be sure to follow your local regulations.
GB-18
01-G2500・G2500 ops_GB_306_四.indd 18
Replace with proper
➡
fuel.
Remove and dry the
spark plug.
➡
Then pull the starter
again with no choke.
Replace with a new
➡
plug.
Case 2. Lack of power/Poor acceleration/
Rough idling
Check fuel for water or
➡
substandard mixture.
➡
Check air filter and
➡
fuel filter for clog-
ging.
➡
Check carburetor for
➡
inadequate adjust-
ment.
Case 3. Oil does not come out
Check oil for substan-
➡
dard quality.
➡
Check oil passage
➡
and ports for clog-
ging.
If the unit seems to need further service, please consult
with an authorized service shop in your area.
Replace with proper
fuel.
Clean.
Readjust speed nee-
dles.
Replace.
Clean.
13.7.4 5:43:58 PM