Common Operations; Logging Into The Om Web - H3C BT1004E Manual

Table of Contents

Advertisement

Log in to the OM CLI: See
2. Procedures
Run the port-speed command on the OM CLI page and set the port rate of port 3 of the cascading
module in slot 1 to 25 Gbps.
<OM>port-speed 25G port-id 3 io 1
Notes
The port rate of BT1004E can be set to 10 Gbps, 25 Gbps, and Auto.
For BT1004E, if the rate of one port is switched, the OM module will automatically switch the
rates of the four ports in the same group.
When the rate of a port is set to "auto", the port will, based on the optical module it identifies,
automatically switch to a port rate that is the same as the optical module.
By default, the port rate of BT1004E is configured as Auto.

7.2 Common Operations

7.2.1 Logging into the OM Web

1. Prerequisites
Power on the chassis.
Obtain the login data of OM module. The default login data of the OM web is shown in
7-1.
Table 7-1 OM login data
Management IP address of the OM
module
User name and password used to
log in to the OM module
2. Procedures
(1)
Ensure that the IP addresses of the PC and OM module are accessible on L3.
7.2.2 Logging In to the CLI of OM
Data
Description
Management IP address (default): 192.168.100.100
Subnet mask (default): 255.255.255.0
User name (default): admin
Password (default): Password@_
7-2
Module.
Table

Advertisement

Table of Contents
loading

Table of Contents