2.13.3
Polarity (Modes)
Option
Description
0
Output not used
1
Normally open, going low
2
Normally open, pulsing low
3
Normally open, one shot low
4
Normally open, one shot low (reactivate)
5
Normally open, one shot low (can reset)
6
Normally open, one shot low (alarm)
7
Normally open, latching low
8
Normally low, going open
9
Normally low, pulsing open
10
Normally low, one shot open
11
Normally low, one shot open (reactivate)
12
Normally low, one shot open (can reset)
13
Normally low, one-shot open (alarm)
14
Normally low, latching open
2.13.4
Time Base
Option
Description
1
200 ms
2
1 sec
3
1 min
4
1 hr
2.13.5
Time Base Multiplier
Enter a value between 01 and 99.
2.13.6
One Shot Mode
When you program the output polarity as one shot,
the time base is multiplied by the time base
multiplier. (For example, if the time base – 2 and the
multiplier – 05, the output operates for 10 sec)
2.13.7
Pulsing Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base x the multiplier. (For example, if you
want the output to pulse 1 sec ON and 5 sec OFF,
you would program time base as one and the
multiplier as five.)
2.14
Time Programming
2.14.1
Entry Time 1
Location
466 to 467
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
2.14.2
Entry Time 2
Location
468 to 469
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
Programming Parameters
2.14.3
Location
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240
sec)
2.14.4
Location
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240
sec)
2.14.5
Location
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240
sec)
2.14.6
Location
Increments of days (tens digit)
Increments of days (units digit)
2.14.7
Location
Default
Increments of 10 sec (0 sec to 150 sec)
2.14.8
Location
Default
Increments of 1 min (0 min to 15 min)
2.14.9
Location
Default
0 – Slowest frequency
15 – Fastest frequency
2.14.10
Location
Default
Increments of 5 min (0 min to 75 min)
2.14.11
Location
Default
Location
466
4
467
1
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Location
Default
Minute of the day (units digit)
468
8
469
2
Exit Time (AWAY/STAY Modes)
470 to 471
Location
470
471
Entry Guard Time For STAY Mode
472 to 473
Location
472
473
Delay Alarm Report Time
474 to 475
Location
474
475
Sensor Watch Time
476 to 477
Location
476
477
Codepad Lockout Time
478
0
Siren Run Time
479
5
Siren Sound Rate
480
7
Auto Arming Pre-Alert Time
481
1
Auto Arming Time
482 to 485
Location
482
483
484
485
EN | 19
Default
12
3
Default
0
0
Default
0
0
Default
0
0
Default
0
0
0
0