INSTALLATION AND USE MANUAL
KÖBER S.R.L.
Edition: 1
VADURI BRANCH
NAME OF APPARATUS / EQUIPMENT
Revision: 3
DOMESTIC HOT WATER STORAGE TANK
Date: 27/07/2022
Form code F-POV-05-07
Page: 1 of 20
KÖBER S.R.L. Dumbrava Rosie
Vaduri Branch
DOMESTIC HOT WATER STORAGE TANK
TYPE BP120L_
V1
INSTALLATION AND SERVICE TECHNICAL MANUAL
Vaduri, Zorelelor Street no.25, Alexandru Cel Bun Commune, Neamt 617511,
Romania, Tel.: +40.233.24.17.46, +40.233.24.19.33, Fax:+40.233.24.19.29
www.motan.ro
rev. 02.04.2020
© KÖBER SRL VADURI BRANCH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Motan BP120L V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kober Motan BP120L V1

  • Page 1 INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 1 of 20 KÖBER S.R.L. Dumbrava Rosie Vaduri Branch DOMESTIC HOT WATER STORAGE TANK TYPE BP120L_ INSTALLATION AND SERVICE TECHNICAL MANUAL Vaduri, Zorelelor Street no.25, Alexandru Cel Bun Commune, Neamt 617511,...
  • Page 2 INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 2 of 20 Dear Client: We congratulate you on your decision to use our product. The MOTAN brand has been on the market since 2002, offering you quality and performance at a reasonable price.
  • Page 3: Table Of Contents

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 3 of 20 CONTENT GENERAL ................................4 Applicable standards and directives ............................ 4 GENERAL PRESENTATION OF THE PRODUCT .......................
  • Page 4: General

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 4 of 20 GENERAL Applicable standards and directives - SR EN 60335-1 "Safety of household and similar electrical appliances. Part 1: General prescriptions"; - SR EN 60335-2-21 "...
  • Page 5: Technical Data

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 5 of 20 Technical data 2.4.1 Dimensional and constructive characteristics Table 1 presents the technical specifications for the boiler. Table 1 Boiler capacity liters...
  • Page 6: Functional Characteristics

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 6 of 20 2.4.2 Functional characteristics Boiler BP120L is recommended for the following installations: - Maximum temperature HDW - 60ºC - Maximum temperature thermal agent on the primary circuit - 80ºC - Working pressure on the HDW circuit –...
  • Page 7: Design Indications

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 7 of 20 3. Using boiler together with electrical heater. Boiler startup when boiler is not full causes damage to the electrical heater. It is recommended to install the electrical heater only in water with low hardness or average hardness up to 14°dH.
  • Page 8: Boiler Equiped With Mixing Valve Kit

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 8 of 20 - thermometer to visualize water temperature inside the boiler; - thermo-insulation (PU foam);...
  • Page 9: Installation Instruction

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 9 of 20 Hydraulic characteristic Considering the flow characteristic, the Caleffi 5213 mixing valve can be used by the consumer at a limited number of consumption bridges.
  • Page 10: Installation

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 10 of 20 Installation ATTENTION! The boiler will be installed only indoors, protected against frost Recommended distances to the walls must be observed in order for the anode and electrical heater to de mounted/ dismounted –...
  • Page 11 INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 11 of 20 The boiler is connected to the domestic water installation (see Figure 2 table 2 for the layout of the connections).
  • Page 12 INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 12 of 20 ATTENTION! The hydraulic safety group is not delivered together with the equipment, but it is obligatory to be mounted in the installation! The hydraulic safety group will contain at least the following elements: - tap, position 2 figure 11;...
  • Page 13: Filling The Boiler With Water

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 13 of 20 3.2.3 Filling the boiler with water To fill the boiler, proceed as follows: - connect the return (TI) and return (RI) of the coil to the CH circuit of the gas boiler;...
  • Page 14: Electrical Diagram

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 14 of 20 3.2.5 Electrical diagram Where: TR1 0-60°C – Capillary thermostat 0-60°C TR2 0-60°C - Capillary thermostat 0-60°C RE 2kW –...
  • Page 15: Use Instructions

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 15 of 20 3.2.5.3 Connecting the boiler to the power supply for the functioning with electrical heater The boiler will be connected to the single-phased 230V - 50Hz grid, directly in the electrical panel / 16A outlet, through a rapid 10A fuse, taking into account color significance as follows: Brown (L1) = phase, Blue (N) = null, Green and Yellow (GND) = earthing.
  • Page 16: Indications Regarding Boiler Decommissioning

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 16 of 20 ATTENTION! It is forbidden to startup the boiler half full in order to avoid damage to the electrical heater! The boiler is equipped with two adjusting thermostats that automatically control the hot water temperature and allow the optimization of the energy consumption depending on necessities.
  • Page 17: Checking Heater

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 17 of 20 anti-corrosion protection is canceled and implicitly the corrosion phenomena of the stainless steel body of the boiler are favored (especially in the area of the welding cords);...
  • Page 18: Spare Parts

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 18 of 20 SPARE PARTS According to figure 16 and table 8. Figura 16 rev.
  • Page 19 INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 19 of 20 Table 8 Poz. Name SAP code Adjustable thermostat 0-60°C PM002310 ON/OFF button PM500167...
  • Page 20: Records Of Interventions

    INSTALLATION AND USE MANUAL KÖBER S.R.L. Edition: 1 VADURI BRANCH NAME OF APPARATUS / EQUIPMENT Revision: 3 DOMESTIC HOT WATER STORAGE TANK Date: 27/07/2022 Form code F-POV-05-07 Page: 20 of 20 RECORDS OF INTERVENTIONS Signature Intervention type Intervention details Date authorized (Defect observed, Replaced spare parts) Maintenance...

Table of Contents