Download Print this page

Sharp R-212B Service Manual page 52

Advertisement

Available languages

Available languages

R-212B
Pin No.
Signal
23
D6
OUT
24
D7
IN/OUT
25
D8
OUT
26
NC
27
F0
28
F1
29
F2
30
F3
31-32
NC
33
XOUT
OUT
34
XIN
35
CNTR
OUT
36
VDD
I/O
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). In
100% POWER operation, the signals hold
"L" level during microwave cooking and
"H" level while not cooking. In other cook-
ing modes (70%, 50%, 30%, 10%) the
signal turns to "H" level and "L" level in
repetition according to the power level.
Terminal not used.
Oven lamp, turntable motor and fan motor driving signal(Square Waveform
: 50Hz).
To turn on and off shut-off relay
(RY1). The square waveform volt-
age is delivered to the relay (RY1)
driving circuit and relay(RY2) con-
trol circuit.
No connection terminal.
IN
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal.
Door opened; "L" level signal.
Terminal not used.
IN
Signal to synchronize LSI with commercial power source frequency.
This is basic timing for all real time process-
ing of LSI.
IN
Signal coming from encoder.
Signal similar to INT. Pulse signals are input into F3.
No connection terminal.
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XIN terminal.
Signal to sound buzzer.
A: Completion sound.
IN
Power source voltage: 0V.
The power source voltage to drive the LSI is input to VDD terminal.
Description
A
16
ON/OFF time ratio in Mi-
cro cooking
(a. 32second time base)
MICRO
ON
OFF
COOK
100%
32sec.
0sec.
70%
24sec.
8sec.
50%
18sec.
14sec.
30%
12sec.
20sec.
10%
6sec.
26sec.
20 msec
During cooking
20 msec
2.4 sec
H: GND
L: -5V
H
L
H : GND
L (-5V)