Appendix C: DCON Command Sets

Command
$AA0CN
$AA1CN
$AA2
$AA4
$AA5
$AA6
$AAC
$AACN
$AAF
$AAI
$AALS
$AALC0h
Description
Span calibration of an analog input channel, N is 0 for
LC-101H and 0 or 1 for LC-102H. Span calibration current
is 5A.
Zero calibration of an analog input channel, N is 0 for
LC-101H and 0 or 1 for LC-102H. Zero calibration current
is 0.1A.
read configuration
Read the synchronized data that was retrieved by the last
#** command.
response
> SOI0000, S is 1 for the first read and 0 for not the
first read
read reset status
!AA1 first after power on, !AA0 others
Read the digital output and input status
response
> 0O0I00, where O is digital output and I is digital input
Clear the status of the latched digital input and output
channels.
Clear the counter value of a digital input channel, N is 0 for
LC-101H and 0 or 1 for LC-102H.
read firmware version
read INIT status
response:
!AA0 -> INIT short to GND
!AA1 -> else
Read the status of the latched digital output and input
channels,
S is 0 to read the low latched status and 1 to read the high
latched status.
response:
!0O0I00
Specify the dependency of the digital output channel on the
LC-101H/LC-102H User Manual
-