I/O Specifications
Module
Digital Input
Channels
Type
On Voltage Level
Off Voltage Level
Input Impedance
Isolation
Relay Output with Load Current Measurement
Channels
Type
Contact Rating
Max. Inrush Current
Number of lighting
fixtures
Operate Time
Release Time
Electrical Endurance
Mechanical Endurance
AC Load Current
Measurement
Power-on Value
Safe Value
LC-101H
1
Wet Contact, 90 ~ 240 V
1
Power Relay, Form C (SPDT N.O+N.C..)
(1).Incandescent Lamp: 40W/ 220VAC * 5 Sets
(2).LED(Electronic ballast): 40W/ 220VAC *8 Sets
Yes, 0 ~ 5 A range with 3% of FSR Accuracy.
LC-101H/LC-102H User Manual
- 7 -
65 VAC
56 VAC
68 KΩ, 2W
3000 VDC
30 A @ 250 VAC
112A /1ms
15 ms Max
22 ms Max.
100,000 ops.
10,000,000 ops
Yes
Yes
LC-102H
2
AC
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-102h

Table of Contents