Model Names Of Indoor/Outdoor Unit; Outdoor Unit Combination - Samsung AM072BXV Series Service Manual

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications

2-2 Model names of Indoor/Outdoor Unit

2-2-1 Outdoor unit combination

■ AM***BXVG* series
Nominal Capacity
Model name for
Numberof individual
combination
outdoor units
Cooling
(Btu/h)
AM072BXVG**
1
72000
AM096BXVG**
1
96000
AM120BXVG**
1
120000
AM144BXVG**
1
144000
AM168BXVG**
1
168000
AM192BXVG**
1
192000
AM216BXVG**
1
216000
AM240BXVG**
1
240000
AM264BXVG**
2
264000
AM288BXVG**
2
288000
AM312BXVG**
2
312000
AM336BXVG**
2
336000
AM360BXVG**
2
360000
AM384BXVG**
2
384000
AM408BXVG**
2
408000
AM432BXVG**
2
432000
AM456BXVG**
3
456000
AM480BXVG**
3
480000
▶ Make sure to use an indoor unit that is compatible with DVM S2.
▶ Indoor units can be connected within the range indicated in following table.
▶ If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating capacity of the indoor unit may decrease.
▶ Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity. 0.5 × Σ( Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ( Outdoor unit capacity)
※ You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is set to 64 since outdoor unit only support up to 64 communication address. Indoor unit address can be assigned from 0~63. If the indoor unit address was assigned from 64~79, E201 error will occur.
※ Maximum 32 Wall-mount type indoor units with EEV (AM∗∗∗∗NQD∗∗∗, AM∗∗∗NVD∗∗∗) can be connected.
Samsung Electronics
Total cooling capacity of the
Rated Capacity
connected indoorunits
Heating
Cooling
Heating
Minimum
(Btu/h)
(Btu/h)
(Btu/h)
(Btu/h)
81000
69000
77000
36000
108000
92000
103000
48000
135000
114000
129000
60000
162000
138000
154000
72000
189000
160000
180000
84000
216000
184000
206000
96000
243000
206000
232000
108000
270000
228000
258000
120000
297000
252000
282000
132000
324000
274000
308000
144000
351000
298000
334000
156000
378000
320000
360000
168000
405000
342000
386000
180000
432000
366000
412000
192000
459000
388000
438000
204000
486000
412000
462000
216000
513000
436000
488000
228000
540000
458000
514000
240000
Maximum number of con-
Maximum
nectable indoorunits
72 (6Ton)
(Btu/h)
93600
12
1
124800
16
156000
20
187200
25
218400
29
249600
33
280800
37
312000
41
343200
45
374400
49
405600
54
436800
58
468000
62
499200
64
530400
64
561600
64
592800
64
624000
64
Combined outdoorunits
AM***BXVG**
96 (8Ton)
120 (10Ton) 144 (12Ton) 168 (14Ton) 192 (16Ton) 216 (18Ton) 240 (20Ton)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
1
1
9