Contact Information ® C O N G R A T U L A T I O N S on your ProSun purchase! Please make sure you read this manual carefully before using this equipment and specifically the maintenance schedule. Keep this manual available for future reference. If you have any questions please contact ProSun directly.
Table of Contents Important Customer Information ................5 Who Should Use, Read, & Understand this Manual ........5 Warning Signs & Symbols …............... 5 Preparing the Product For Use ................8 Export …....................... 8 Transportation …..................8 Delivery …..................... 9 Ventilation …....................
Page 4
How to Operate the Equipment ……………………………………………………….. 20 Normal Equipment Operation & Software ………..……………………....21 Operating Modes ………………………………………………………………..21 Standby Mode ………………………………………………………...... 21 In Session Mode ………………………………………………………...... 21 Cool Down Mode ………………………………………………………………..21 Service Mode ………………………………………………………………………… 21 Starting the Session ……..………………………………………………..22 Stopping the Session ……....………………………………………………..
A copy of the user manual should be readily available.This manual may include features that are not included for your bed. Any service work outside of the preventative care table in this manual should be done by a ProSun authorized technician. Warning signs and symbols Danger and Safety Symbols: Danger Hazard exists for human health.
Page 6
High Voltage exists and is dangerous for human contact. Caution Symbol means to proceed with caution and follow instructions careful ESD-Sensitive devices, do not touch without using necessary proper precautions. Type B Applied Parts Symbols found on equipment and packaging: Follow and read instructions thoroughly prior to using equipment.
Page 7
Protective earth connections. Recyclable Material Polystyrene Cardboard Mixed Paper Wood Waste of electrical and electronic equipment must not be disposed as unsorted municipal waste. It must be collected separately, and must be disposed as per local regulations. Alternating Current. Single Phase Three phase alternating current.
ProSun does not assume any liability if there is non-compliance outside of the intended sale territories of the United States or Canada. The exporter assumes their own risk by removing this equipment outside of the United States or Canada.
Coordinate with ProSun installation department to set up delivery and installation details. In a commercial setting an external timer is required. ProSun recommends to use this accesory (T-Max Flushmount G2).
Page 10
ProSun and all authorized parties shall reserve the right to refuse to install equipment into any room which has not been properly prepared in accordance with the electrical specification and room requirements.
Commissioning of the equipment The equipment is initially commissioned by a certified ProSun technician. The device will be properly assembled and handed over ready for us. In order to properly commission the equipment, the business owner must ensure that the location is ready prior to the equipment being installed.
Device Description X3 Canopy 1. Head end of Unit 2. Cover plate 3. Deco (optional) 4. Ballasts 5. Side Bars 6. Endcaps 7. Canopy Acrylic X3 Bench 1. Lamps 2. Cover plate 3. Side Bar 4. End Cap 5. Bench Acrylic 6.
90.1 inch Dimensions 90.1 inch 90.1 inch 92.5 inch 33.5 in 33.5 in 33.5 in 45.0 in 45.0 in 45.0 in 90.1 inch 45.2 in 45.2 in 53.7in 33.5 in 53.7in 20.0 in 20.0 in 45.0 in 49.2 in 47.2 in 47.2 in 49.2 in 61.0 in...
Technical Data Electrical Specifications RenuvaSkin L3200 Power consumption rating: 10 Amp Electrical Rating: 230V 3~ 10A 60Hz Rated Fuses: 25 amp 3-pole Continuous Operation: Continuous operation for a maximum of 15 minutes. Load on the base plate: Max 250lbs or 113 Kg...
Page 16
Please insure that your electrician and/or installer, reads this user’s manual carefully prior to the installation of your ProSun unit. You will need a buck booster if voltage requirements are not met. Service personnel should be authorized by ProSun to perform work on equipment and should have knowledge of equipment and read the full manual.
Electrical Connections Live Components Risk of fatal injury due to electrical shock when touching live parts. DANGER! Risk of electrical Shock To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective earth. WARNING! Both the power supply and the related connection work must comply with national standards.
Before your session Check for any conditions mentioned in the manual that may prevent you from using the equipment. Make-up and cosmetics Do not wear make-up when using the equipment. Remove all make-up prior to session. Make-up clogs the pores in your face. Jewelery Remove all jewelery prior to use, including piercings.
Non-approved cleaning agents should not be used, especially products including lysoform, ethyl alcohol or other liquids containing alcohol. If used the warranty will be voided! ProSun® recommends the use of Lucasol One Step when cleaning acrylic sheets. Acrylics in equipment are extremely porous and should not be cleaned/disinfected with non-approved products.
Operation of Equipment Obligations of the business operator • All danger and safety labels should be attached to the equipment and clearly visible to the user. You should not remove these labels at any time! • No safety devices( i.e. temperature sensors) may be removed, deactivated or otherwise bypassed from the equipment, as it can cause safety issues and impair the proper functioning of the equipment.
Normal Equipment Operation and software Operating Modes: There are 4 different operating modes for this equipment. Standby Mode The bed is in an idle state, it is connected to the power but is currently not in use. The lamps in the unit are not turned on at this time. While in Standby mode you can change to In Session mode by starting a session or go into service mode by entering into the parameters.
In Session Mode The following description is for a unit that has all possible features, some of these features may not be available for your unit or market. Starting the session The session will automatically begin after the external timer delay time has expired. During the preset delay time the session can be started by manually pressing the START button (2) on the control panel, thereby overriding the delay time.
Waste of electrical and electronic equipment must be disposed as unsorted municipal waste. It must be collected separately, and must be disposed as per local regulations. Contact ProSun International LLC or an authorized representative for information concerning the decommissioning of your equipment.
Control Functions Not all options shown below are applicable on this device and in the US Market. General Controls: Function Description Additional Information Start Switches the lamps on Stop Switches the lamps off Hit stop once to pause the session and hit stop twice to end session.
Indicator Lights: All indicator lights will be on the display of the unit and will show green when ready to use or for selection purposes. The machine is set up for standard use with an external timer or a coinbox. If the machine must function without the external timer or coinbox, i.e.
Page 26
Controls in combination with an external timer or for coin-operated use: The bed will be started automatically when the external timer or coin-operated equipment switches on. The equipment will pause when the “stop” button is pressed once. If stop is pressed more than once, the equipment will remain paused.
Reading the hour counters and software To be able to read teh hour counter for the lamp hours, press the HIDDEN button and DECREASE body cooling button at the same time. The number that shows up multiplied by 10 is the total hours on your lamps.
Communication fault between control and switch parts. Error! Communication fault switch part. Error! Unknown phase. If one of these error messages appears on your display, you must stop using the unit immediately and contact ProSun. WARNING! 28 Manual Rev 1...
Accidental reactivation can result in serious accidents. Immediately after deenergizing the equipment, secure all switches or fuses used for deenergizing against being switched on again. For more maintenance information please visit our website at: www.prosun.com/customer-service Manual Rev 1...
The table below is a preventative care table that can be done by any unskilled person, if any service outside of this table is needed please contact ProSun immediately and this would should only be done by a certified technician.
Page 31
NOTE: For thorough cleaning and disinfection, the product you are using has to remain in contact with the surface that is being cleaned and disinfected for a specific amount of time, as mentioned on the instructions of the product. The specifc amount of time will depened on the type of cleaner/disinfectant that you are using.
Maintenance by skilled persons: ProSun recommends having an annual inspection by a certified technician to review connections, check for lose wiring, check the power cords and review all other high voltage components. At this time the certified technician can dust all electronic components.
Damage to equipment by user or Contact ProSun for replacement. Non- cleaning skilled person can replace acrylic. Any troubleshooting outside of the above mentioned guide should be done by a certified technician. Contact ProSun to schedule service with a certified technician. Manual Rev 1...
Replacement of Components WARNING: Before doing any work on this machine, whether it be an unskilled person or a certified technician, ALWAYS disconnect the power at the main circuit breaker(or, if the main power cable has a wall plug, pull it out). WARNING! IMPORTANT: Only use manufacturer-authorized replacement components.
Replacing the Lamps Remove acrylics before replacing lamps. Lamp replacement: Holding the lamp at both ends, turn it counter-clockwise until the bi-pins can slide easily out of the lamp holder socket, and slowly take it out of the unit. Clicks will be heard as the socket incrementally rotates.
Assembly Introduction Required for assembly (not included): • Preferably 2 wrenches to tighten bolts and nuts • Power adapter kit (230V for commercial use, for warranty to apply voltage must be between 215-230 V) *Make sure you write the Serial Number (located on the Control Panel) down on the previous page and store the manual somewhere you can easily access.
Page 38
Symbols Warning symbol: People with long hair should wear a hairnet! Warning symbol: Wear the protective goggles provided Warning symbol: Attention please! Warning symbol: Sunbed should be disconnected from power source Warning symbol: Remove plug from socket Warning symbol: Not for household use Symbol: Facial tanner Symbol:...
Revised June 2019 Warranty Period: Provided it is still owned and operated by the original owner, PROSUN warrants all equipment manufactured or imported by it to be free from defects in material under normal use and service. Warranty Periods as specified below are from the date of invoice. The warranty is non-transferable and is only valid for the original purchaser of the equipment.
Page 49
Exclusivity of Warranty: This warranty is the only warranty made by PROSUN and may only be modified or amended by a written instrument signed by a duly authorized officer of PROSUN. PROSUN’s sole and exclusive liability and Purchaser’s sole and exclusive remedy under this warranty shall be,...
Page 50
RESPECT TO THE PRODUCTS DELIVERED HEREUNDER OR SUBSEQUENT USE THEREOF. Limitation of Liability: PROSUN shall not be liable for any loss, damages, or penalty resulting from failure to perform any of its obligations under this Agreement due to major force or any cause beyond its reasonable control.
Need help?
Do you have a question about the RenuvaSkin L3200 and is the answer not in the manual?
Questions and answers