Operation
9.5 "Crater repeat" operation
To repeat crater operation turn ON the torch switch within a preset time (Trep)* after turning off the previous crater
operation. (In this manner, it is possible to repeat the cra- ter operation again and again.)
*: Trep: About 2 seconds
Note:
If the torch switch is not turned on within the preset time, the function is cancelled.
● To stop welding, raise the torch until arc is cut.