The Welding Machine Factory Defaults Reset - Panasonic YD-350GY4 Operating Instructions Manual

Digital igbt controlled mig/mag arc welding power source
Table of Contents

Advertisement

8.1.2
"CALL" and "RECORD"
Reminder
when delivery, Record & Call functions are set as disabled status.
●"Call" is a function to use stored welding conditions and "Record" is to store the well-tuned welding conditions.
Record/Call operation is applicable to the set values of current ・ voltage, spot welding time, arc characteristics,
penetration control, welding control, pulse ON/OFF, material, wire diameter, gas and F. Adj.
" Call " operation
Reminder
During the selection of Call, welding condition can NOT be changed (gas check and manual wire
feeding function work.)
No.
Select Call in ○
1
12
Select channel (CH1-CH100) to be called in ○
(It alternately shows "CH" and current set value in ○
2
voltage set value in ○
At present, ( welding condition is already being called) welding can
3
start.
After operation finishes, select ○
4
" Record " operation
Reminder
During Record operation, welding can't start. (Gas check works.).
No.
Select Record in ○
1
Select the channel (CH1-CH100) to be used in ○
(It alternately shows "CH" and current set value in ○
2
voltage set value in ○
After operation finishes, select ○
3
now data recording finishes.
Note:
During Call operation,

8.2 The welding machine factory defaults reset

If 7-segment LED cannot display correctly after turning ON the power source, the damage of internal data may
happen. Please follow the steps here to restore machine to factory settings.
The operation sequence
1. Disconnect power source ;
2. After connecting the power source, at the moment when the software version is shown, hold【lock】 and
【welding control】button at the same time for 2 seconds. After welding machine finishes the display of the
software version, the display shown on the below picture happens. Thus the default setting is done successfully.
Please disconnect power source;
Note:
Only when the display shown on the above picture on the welding machine, the power source can be switched off,
otherwise wrong operation would lead to the failure of the operation. And the second step should be done again.
3. After turning the power source again, welding machine restores to factory settings;
4. Because the recorded data is reset to factory settings, please set according to your requirement.
Note:
During welding, there are certain errors of current and voltage between the value shown on LED and preset value.
It's not a machine problem. During actual welding, the factors such as gas, wire diameter, welding technique and
extension length etc. can generate the above-mentioned errors.
Operation
( as shown in the picture on the right )
)
5
and return to " welding " mode
12
Operation
( as shown in the picture on the right )
12
)
5
and return to " welding " mode. Till
12
13
14
15
16
17 operation does not function.
- - -
Settings
7
, channel and
2
.
7
,
channel and
2
2
5
- - -
25
7-segment LED
C H
O F F
7-segment LED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yd-500gy4Yd-350gy4hjeYd-500gy4hje

Table of Contents