Welding Wire Inching; Checking Shield Gas - Panasonic YD-350GY4 Operating Instructions Manual

Digital igbt controlled mig/mag arc welding power source
Table of Contents

Advertisement

8.3 Welding wire inching

Do not perform wire inching operation or pull the torch switch with your eyes, face or body close to
the end of the welding torch. Wire may stick into your eye, face or body.
In case of using a torch cable with the resin liner, straighten the torch cable and reduce the feed amount (current) to
a half or less before performing the wire inching. Please replace any damaged liner or cable with a new one as use
of them may cause gas leak or insulation deterioration.
Attention
Use of a wire in small diameter may cause unstable wire feeding. In case of using such wires, please feed the wire at
low speed or contact Panasonic representatives.
Press the "INCHING" (8) button on the operation panel
to feed the wire manually. The wire is fed forward while
this button is pressed. And the lamp is on while
feeding the wire.
Inching is available when the welder is in standby
*
state.
Current set value for the main welding is used to
*
determine the wire inching speed.
If this button is pressed when the "F.
*
ADJ" or "RECORD" ("FUNCTION" (12)") is
selected, the "no" "Arc" are displayed on (2)
and (5) respectively to indicate that it is
not possible to feed wire.

8.4 Checking shield gas

Check the shield gas if necessary.
(1)
Check and make sure that the Flow
adjustment knob is place in the "SHUT"
position.
(2)
Turn on the gas cylinder main valve.
(3)
Press the "GAS CHECK" (14) button.
(4)
Turn the flow adjustment knob gradually
in the "open" direction until the flow
rate becomes appropri-
ate.
Wire extends out from the end of the welding torch and may stick into the
eye, face or body, which can cause injury.
Applying high-speed wire inching with the torch cable bent may cause the
wire to run through the resin liner and the cable.
In case of using a welding wire with a small diameter (0.8 mm
Prior to checking, read the operating instructions of the applied gas regulator.
Make sure to read and understand safety precautions.
Settings
1
2
3
9
8
11
26
2
2
or 0.9 mm
)
5
4
12
13
14
10
15
16
17
Gas cylinder
main valve
Flow adjustment knob
18
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yd-500gy4Yd-350gy4hjeYd-500gy4hje

Table of Contents