5 Names and functions
5.1 The power switch
5.2 The output terminal area
Regarding connection and disconnection of the cable, to avoid electric shock and
malfunction, please be sure to cut off the switch of distribution box and then start the
operation.
Names and functions
About power switch:
● When the power switch is turned off automatically, do not turn it on
again. (Consult with sales distributor of Panasonic representatives.)
● When activating a power generator, turn off the power switch.
The connection and disconnection operation of the power source
● Turn the power source switch knob clockwise to connect power
source. About one 1 second later, LED display shows software
version information.
● The software version is shown for about 4 seconds. Then AC
contactor is switched on and cooling fan starts to rotate.
①
(-) base metal connection
Connect the base metal cable to the "(-) base metal terminal".
( + ) welding gun cable connection
Connect the power cable drawn from the wire feeder to the (+) torch terminal.
control cable socket (16 cored )
Please firmly connect the socket with the wire feeder
②
③
※ 1
16 cored cable.
12