Section 6. General Maintenance and

Troubleshooting

Before proceeding, make sure the pump system is fully
functional and activated. Also, ensure all air is purged
from plumbing lines.
6.1
Troubleshooting
Problem
The waterfall is not
completely smooth. A gap
or gaps in the sheet of the
waterfall is present.
Where multiple waterfalls
are installed, one of the
waterfalls is stronger than
the other(s).
6.2

Freeze Protection and Winterizing

In order to prevent freeze damage to the system, the
plumbing to the unit must be installed so water drains
easily from the system. The Sheer Descent and Fiber
Fall waterfalls have been engineered to allow only a
minimum of water to stay in the unit as long as the
plumbing is installed properly. Blow out all water from
the pipes and Sheer Descent or Fiber Fall unit. Follow
the normal procedures for winterizing.
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
Zodiac Pool Systems Canada, Inc.
2115 South Service Road West, unit 3
Oakville, ON L6L 5W2
1.888.647.4004 | www.zodiacpoolsystems.ca
©2015 Zodiac Pool Systems, Inc. H0347100 Rev D
ZODIAC
®
is a registered trademark of Zodiac International, S.A.S.U., used under license.
All trademarks referenced herein are the property of their respective owners.
Zodiac
®
Sheer Descent
Cause
Debris has lodged in the
opening of the waterfall.
Dirty filter, pump basket
or both has slowed down
the flow to below proper
standards.
Waterfall flow valve(s) are
out of adjustment.
Waterfall radius was field
cut and spacers were not
removed.
The water supplied to
the units is not properly
balanced.
Improper loop plumbing
installation.
and Fiberfall
®
Water Features
®
Solution
Use a credit card or similar object and gently position it
inside the opening while the waterfall is on. Slide it along
the opening to the point where the debris is located and
gently pull the debris through the opening. Do not use a
metal tool.
Clean filter, pump basket or both.
Adjust water flow valve(s).
Refer to Section 4.4 for proper spacer removal
instructions.
Adjust the valves for each waterfall until the proper
effect and balance is achieved. See Figure 15 for valve
location.
Correct loop plumbing installation. Refer to Figure 16 for
proper loop plumbing setup.
|