Plumbing A Single Unit; Plumbing Multiple Units; Cutting The Lip For Radius Or Custom Installations - Zodiac Sheer Descent Installation And Operation Manual

Water features
Table of Contents

Advertisement

Available languages

Available languages

Zodiac
®
Sheer Descent
and Fiberfall
®
Water to
sheer descent
Figure 13. Three-Way Valve Plumbing Setup
the Sheer Descent waterfall. A Jandy three-way valve
is suggested to be used as the "T" from the return line
of the pool to the Sheer Descent waterfall. A properly
plumbed valve in that position will allow full control of
the water to the Sheer Descent, as well as to the rest of
the pool. In most cases, this valve can be located after
the filter near the equipment pad. See Figure 13.
NOTE All water to the Sheer Descent must be filtered.
Those systems using a separate pump must
use our separate energy filter (p/n 3456) or
equivalent to prevent debris from entering the
Sheer Descent unit.
4.2

Plumbing a Single Unit

All back feed Sheer Descent waterfalls have the
equivalent of standard 1½ inch inside and 2 inches
outside pipe protruding from the back of the unit. For
waterfalls 1 through 8 feet in length, this fitting is
located in the center of the back of the waterfall.
Standard 1½ inch and 2 inch PVC fittings will glue
in and over the 1½ inch slip by 2 inch insert fitting
provided on all Sheer Descent waterfalls.
Ensure plumbing lines to unit are clear of debris.
Ensure plumbing is properly sized.
Notch in beam
Back Feed plumbing for
units 1 feet through 8 feet.
Figure 14. Single Sheer Descent Plumbing Setup
|
®
Water Features
Installation and Operation Manual
Line bypass to pool
Jandy
®
three-way
valve
Pump
Filter
Suction
from pool
Beam
ENGLISH
NOTE A flow control valve must be plumbed in a
convenient location on the supply line for
regulation of the water supply to the unit. See
Figure 14.
4.3

Plumbing Multiple Units

Plumbing two or more Sheer Descent waterfalls
together is done in exactly the same way as the
installation procedure for a single unit, explained
previously, with the exception that additional two-way
valves are required for each Sheer Descent waterfall.
See Figure 15. The loop plumbing option can also be
used for two or more units. See Figure 16.
Make sure no debris is in any of
the plumbing lines in the unit
Option #1 - Sheer Descent
waterfall back feed plumbing
for multiple units.
Figure 15. Multiple Sheer Descent Plumbing Setup
Make sure plumbing lines are clear of debris.
Jandy
®
Valve
Option #2 - Sheer Descent waterfall
back feed loop plumbing for
multiple units.
Figure 16. Multiple Sheer Descent Loop Plumbing
Setup
4.4
Cutting the Lip for Radius or Custom
Installations
The extended lip Sheer Descent waterfall can be custom
cut in the field to meet specific needs, such as radius,
irregular shapes, etc. In order to custom fit the waterfall,
carefully measure the amount of extended lip to be
Page 13
Jandy
®
Valve