Graco Gusmer Reactor H-25 Operation page 17

Hydraulic, heated, plural component proportioner
Table of Contents

Advertisement

3.
Connect electrical cord
Power cord is not supplied. See T
Table 2: Power Cord Requirements
Part No.
Model
253200
H-25
253201
H-25
253202
H-25
253203
H-XP2
253204
H-XP2
253205
H-XP2
253206
H-25
253207
H-25
253208
H-25
253300
H-25
253301
H-25
253302
H-25
253303
H-XP2
253304
H-XP2
253305
H-XP2
253306
H-25
253307
H-25
253308
H-25
a.
230V, 1 phase: Using 5/32 or 4 mm hex
allen wrench, connect two power leads
to L1 and L2. Connect green to ground
(GND).
L1
L2
311299C
2.
ABLE
Cord Specification
2
AWG (mm
)
6 (13.3), 2 wire + ground
10 (5.3), 3 wire + ground
10 (5.3), 4 wire + ground
4 (21.2), 2 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 4 wire + ground
4 (21.2), 2 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 4 wire + ground
6 (13.3), 2 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 4 wire + ground
4 (21.2), 2 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 4 wire + ground
4 (21.2), 2 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 4 wire + ground
GND
ti2515b
b.
230V, 3 phase: Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect green
to ground (GND).
L1
L2
L3
c.
380V, 3 phase: Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect neutral
to N. Connect green to ground (GND).
L1
L3
L2
N
Setup
GND
ti3248b
GND
ti2725a
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gusmer reactor h-xp2