Download Print this page

Sub-Zero UC-15IPO Use And Care Manual page 11

Undercounter ice machine
Hide thumbs Also See for UC-15IPO:

Advertisement

Available languages

Available languages

T R O U B LE S HO O T I NG
Troubleshooting
U N IT O P E R AT I O N
Ice machine does not operate.
Verify power is on.
Verify electrical power to ice machine and home circuit
breaker is on.
No light.
LED interior lighting must be replaced by Sub-Zero
factory certified service.
Ice machine operates, but no ice is produced.
Verify connection to water supply.
Verify water filter is not clogged. Replace water filter,
then follow cleaning and sanitizing procedure on page 7.
Verify spray nozzles are not blocked. Follow cleaning and
sanitizing procedure on page 7.
Verify water pressure at 20 psi
Verify bin thermostat adjustment, refer to page 5.
Verify ambient air temperature between 50°F
100°F
for indoor model and between 50°F
(40°C)
and 110°F
for outdoor model.
(45°C)
Unit requires frequent cleaning and sanitizing.
Consult a qualified professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certified Service to disas-
semble unit and thoroughly clean and sanitize.
to 80 psi
.
(1.4 bar)
(5.5 bar)
and
(10°C)
(10°C)
IC E PR OD U C T IO N
Low ice production.
Clean condenser area, refer to page 8.
Verify connection to cold water supply.
Verify water filter is not clogged. Replace water filter,
then follow cleaning and sanitizing procedure on page 7.
Verify operation of water inlet valve.
Verify ambient air temperature between 50°F
100°F
for indoor model and between 50°F
(40°C)
and 110°F
for outdoor model.
(45°C)
Contact Sub-Zero Factory Certified Service if unre-
solved.
Poor ice quality, cubes are shallow, incomplete or white.
Follow cleaning and sanitizing procedure on page 7.
Replace water filter, refer to page 8.
Adjust cube weight, refer to page 5.
Verify water softener is working properly (if applicable).
Consult a qualified professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certified Service to disas-
semble unit and thoroughly clean and sanitize.
and
(10°C)
(10°C)
|
subzero.com
11

Advertisement

loading

This manual is also suitable for:

Uc-15ipUc-15ioUc-15i