CARE AND MAINTENANCE
8. Using wrench (J), unscrew the Fluid Nozzle
(B) by turning counterclockwise and place it
in the secondary container to soak.
9. After 3-5 minutes, remove each item and use a clean dry towel to wipe off
the entire item and inspect it for any remaining paint or dirt to wipe remains.
IMPORTANT:
To ensure all residue of material is removed from the part, use
a blow gun with an approved OSHA gun tip to blow any excess cleaning
solution off the part that a rag cannot get to.
If paint or dirt debris is still present, use a non-wire soft bristle brush and
brush the area.
NOTE:
Soaking of parts may require longer to get all paint residue off the
part.
RE-ASSEMBLING SPRAY GUN
1. Screw the Fluid Nozzle (B) into the face of
the spray gun by turning it clockwise, using
the wrench (J) to tighten securely.