Sanyo PLC-XF1000 Owner's Manual page 67

12000 ansi xga quadrive
Hide thumbs Also See for PLC-XF1000:
Table of Contents

Advertisement

appears on the screen
appears on the screen
The image is out of focus.
The image is not bright
enough.
The color is strange.
The image is Left/Right
reversed.
The image is Top/Bottom
reversed.
The image is distorted or
runs off.
Auto PC adjustment
function does not work.
Some displays are not
seen during the operation.
The setting does not
remain after turning off
power.
Power management
function does not work.
Image disappears
automatically.
Capture function does not
work.
Some menus cannot be
selected.
– The end of lamp life is approaching. Replace the lamp with a new one promptly.
(See page 55.)
– The filter is out of scroll. Replace the filter cartridge with a new one promptly. (See
pages 57-58.)
–Adjust the focus of the projector.
–Check Projection Lens to see if it needs cleaning.
Note: Moving the projector from a cool temperature location to a warm temperature
location may result in moisture condensation on Projection Lens. In such cases,
leave the projector OFF and wait until condensation evaporates.
– Projecting from excessive slant angle to the screen may cause keystone distortion and
partial imperfect focus.
–Check if "Contrast" or "Brightness" are adjusted properly. (See page 45.)
–Check if "Image level" is selected properly. (See pages 38, 42.)
–Check the Lamp control function. ( See "SETTING" section on page 51.)
– Check the Lamp 1/2 replace indicators. If it lights, the end of lamp life is approaching.
Replace the lamp with a new one promptly. (See page 61.)
– The image is darker when 1 lamp mode is selected, compared with 2 lamp mode.
Check the lamp mode at SETTING section on page 51.
–Check the Input signal, color system, video system, or computer system mode.
–Check the Ceiling / Rear function. (See pages 40, 44.)
–Check the Ceiling function. (See pages 40, 44.)
–Check "PC Adjust" menu or " Screen" menu and adjust them.
– Check the Input signal. Auto PC Adjustment function cannot work when 480p, 575p,
720p, 480i, 575i, 1035i, or 1080i is selected or when the digital signal is input into DVI
terminal. (See page 35.)
–Check the Display function. (See page 48.)
– Make sure you selected "Store" after adjusting settings. Some settings cannot be
stored if not registered with "Store" .
– Power management function cannot work while "Freeze" function is running or the
shutter is closed.
– Check the power management function in the Setting. The power management is set to
"On" at the factory.
–Check the connection to see if there is signal.
–Each of the Video Input and Computer Input has a limit on selectable menus.