Electrical Connection; Setting A Permanent Temperature Limit; Operation; Cleaning - STIEBEL ELTRON SNU 5 Plus Operation And Installation Instruction

Small water heater (non-pressurised)
Table of Contents

Advertisement

Available languages

Available languages

Operation

u Either open the DHW valve of the tap or set the mono lever
mixer tap to "hot" until the water that flows out is free of air
bubbles. This process may take several minutes.
u Check the entire hydraulic installation for tightness.
6.2

Electrical connection

WARNING
Electrocution when the appliance is permanently con-
nected to the mains
When permanently connected to the power supply us-
ing a dedicated junction box, the appliance must be
able to be isolated from the mains power supply by
an isolator that disconnects all poles with at least
3 mm contact separation.
WARNING
Electrocution
Ensure that the appliance is connected to the earth
conductor.
Overvoltage
The voltage specified on the type plate must match
the mains power supply.
u Establish the electrical connection by plugging in the stand-
ard plug or by a permanent connection.
The following electrical connections are permissible:
Connection to a freely accessible standard
socket with matching plug
Permanent connection to an appliance socket
with earth conductor
6.3

Setting a permanent temperature limit

D0000105858
Placing the limiting ring behind the temperature selector allows
you to limit the setting range of the temperature selector to a
specific maximum temperature.
u Turn the temperature selector to zero (fully anti-clockwise).
u Pull off the temperature selector.
u Undo the two screws securing the limiting ring in the cas-
ing.
u Re-insert the limiting ring with the required temperature
limit.
u Secure the limiting ring in the casing with the screws.
16
| SNU 5 Plus | AU | GB | 1 kW
NOTICE
SNU 5 AU
Plus GB
x
x
u Push the temperature selector back on its shaft in the zero
position (fully anti-clockwise).
7
Operation
You can set the required hot water outlet temperature steplessly
at the temperature selector (2). During the heating process, the
heat-up and index indicator (1) lights up.
D0000105766 | CO
1 Heat-up and index indicator
Depending on the system, the actual temperatures may vary
from the set value.
On this setting, the appliance is protected from frost. The tap and
the water line are not protected
E
Recommended energy saving setting ECO (approx. 60 °C), minor
scaling
85 Highest temperature that can be set
SNU 5
NOTICE: The qualified contractor can set a permanent temperat-
ure limit on the appliance.
x
8

Cleaning

Almost every type of water will deposit limescale at high tem-
peratures. Limescale will settle inside the appliance and affect
its function and service life. The heating elements must there-
fore be descaled if necessary. A qualified contractor who is
aware of the local water quality will tell you when the next de-
scaling is due.
u A damp cloth is sufficient for cleaning the appliance. Never
use abrasive or corrosive cleaning agents.
u Check the tap regularly. You can remove limescale deposits
at the outlet using commercially available descaling agents.
9

Maintenance (qualified contractors)

Electrocution
Risk of serious injury from an open appliance
u Before any work on the appliance, disconnect all
poles of the appliance from the power supply.
u Dismantle the appliance for maintenance work.
2 Temperature selector
WARNING
www.stiebel-eltron.com
1
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snu 5 plus auSnu 5 plus gbSnu 5 plus 1 kw

Table of Contents