I — INTRODUCTION
The Kepco HSF-PFC 50 Watt series hot swappable, high
frequency switching, plug-in power supplies with built in
power factor correction employ forward conversion and are
designed to operate in a fault tolerant power system with
either a-c or d-c input. A thermistor soft-start circuit limits
start-up surge. A built-in forced current share circuit and
OR-ing diodes allow configuration for hot-swap and paral-
lel-redundant N+1 operation.
These power supplies are designed to be installed in
Kepco's RA 19-(X)B Rack Adapters (Figure 2). RA 19-6B
accepts up to six 150W units, RA 19-7B accepts up to three
150W units, and up to four 50W or 100W units and RA 19-
8B accepts up to eight 50W or 100W units. The applicable
RA 19-(X)B Operator Manual can be downloaded from the
Kepco web site at:
www.kepcopower.com/support/opmanls.htm#ra19-xb
All input/output connections are through a 24 pin connector
that plugs into the rack adapter. All external connections
are made through the rack adapter.
MODEL
OUTPUT VOLTS, d-c (NOMINAL)
ADJUSTMENT RANGE
OUTPUT CURRENT (NOMINAL)
CURRENT LIMIT
OUTPUT POWER (MAX.)
SHORT CIRCUIT CURRENT
RIPPLE AND NOISE
(mV p-p)
0-40°C, 10-100%
LOAD
OVERVOLTAGE SETTING
(25 °C, NOM. INPUT)
SENSE RESISTOR (RS) value
(1) Derates same as Output Power.
(2) Current Limit is rectangular. After the overload is removed,
output is automatically restored.
(3) See power derating curve, Figure 3.
(4) 28V Model available with T, C, X and Y Options only.
KEPCO, INC.
131-38 SANFORD AVENUE
"
©2010, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
KEPCO SINGLE OUTPUT 50 WATT
HOT SWAP PLUG-IN POWER SUPPLIES
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-PFC 50W SERIES
HSF
3.3-10PFC
3.3V
2.8 - 3.4V
(1)
10A
(2)
13.1A min
(3)
33W
(2)
16A
switching (typ)
80
spike noise
120
(d-c—50MHz)
3.9 - 5.1V
(5)
0.01 Ohm
" FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 "
http://www.kepcopower.com "
Six models may be selected for outputs of 3.3, 5, 12, 15,
24, or 48V (see Table 1).
When the input is cut off, the output is maintained for 15
milliseconds minimum. If the power supply shuts down due
to an output overvoltage condition, it is then necessary to
wait 30 seconds minimum before turning the unit on again.
EMI filtering is designed to meet FCC Class B rating and
VDE 0871 Class B rating. Table 1 lists specifications for
each model of the HSF-PFC 50 Watt Series. See "SPECI-
FICATIONS" on page 4 for common specifications.
OPTIONS. Options are identified by suffix: T (-PFCT)
offers improved efficiency, less weight, and the addition of
a 28V, 50W model; C (-PFCC) offers current monitoring
via an integral current sensing resistor (includes option T),
X (-PFCX) offers remote on/off (includes option T); and Y
(-PFCY) includes options C, X and T.
HSF
HSF
5-10PFC
12-4.3PFC
15-3.5PFC
5V
12V
4.3 - 5.3V
11.4 - 12.6V
13.5 - 16.2V
10A
4.3A
10.5A min
4.5A min
3.6A min
50W
51.6W
12.6A
5.6A
80
100
120
150
5.7 - 6.4V
13.5 - 15.5V
16.8 - 18.8V
0.01 Ohm
0.02 Ohm
0.03 Ohm
(5) Sense resistor Included with C and Y models only.
(6) Peak current and thermal protection applicable to some 24V models:
standard (no options) and C option only.See Figure 1 for peak power
requirements.
(7) For 24V Model,s T, X and Y options only.
email: hq@kepcopower.com
228-1532 REV 9
HSF-PFC
50W SERIES
HSF
HSF
24-2.2PFC
28-1.8PFC
15V
24V
22.5 - 25.5V
22.4 - 30.2V
2.2A
3.5A
(6)
(3.2A Peak)
3.3A min
1.9A min
(7)
(2.3A min)
52.5W
52.8W
5.4A
6.2A
100
100
150
150
26.8 - 30.3V
32.0 - 35.0V
0.05 Ohm
0.05 Ohm
FAX (718) 767-1102
HSF
HSF
(4)
48-1.1PFC
28V
48V
44.0 - 52.0V
1.8A
1.1A
1.15A min
50.4W
52.8W
1.7A
2.4A
150
130
200
200
54.8 - 59.9V
0.1 Ohm
1

Advertisement

loading

Summary of Contents for KEPCO HSF-PFC 50W Series

  • Page 1 (-PFCY) includes options C, X and T. All input/output connections are through a 24 pin connector that plugs into the rack adapter. All external connections are made through the rack adapter. TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-PFC 50W SERIES MODEL 3.3-10PFC 5-10PFC 12-4.3PFC...
  • Page 2: Forced Current Share Circuit

    IMON pins (requires millivoltmeter, range 0 to 200mV). applicable RA 19-(X)B Manual for details. Accuracy is ±10%; contact Kepco if greater accuracy is required. There is no isolation between ±IMON, alarm cir- cuit and d-c output. Refer to the applicable RA 19-(X)B Manual for details.
  • Page 3 (If forced current sharing at less than to mate with the corresponding connector in the Series RA 10% nominal current per supply is needed, contact Kepco 19-(X)B Rack Adapter. application engineering.) Remote sensing is recom- mended.
  • Page 4: Specifications

    III — SPECIFICATIONS The following specifications apply to all HSF-PFC 50 Watt Series models (also refer to Table 1). Other models are also available; consult your Kepco representative for their specifications. INPUT: Voltage: 120V a-c/240V a-c nominal; Range 95-265V a-c; 125-370V d-c. (polarity insensitive) Frequency: Nominal 50-60 Hz;...
  • Page 5: Installation

    5-10 Hz, 10 mm amplitude. 10-55 Hz, 2g acceleration. FUSE: Slow Blow, 2A, 250V; (5 x 20 mm), Littelfuse, P/N 215002PG; SHOCK: (non-operating, one-half sinusoidal pulse, three Kepco P/N 541-0137. shocks to each axis): Acceleration: 20g DIMENSIONS: See Figure 6. Duration: 11ms +5ms WARRANTY: 5 years.
  • Page 6 FIGURE 6. HSF-PFC 50W POWER SUPPLY OUTLINE DRAWING KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102 http://www.kepcopower.com " email: hq@kepcopower.com 228-1532 REV 9 090310...