Pressure Testing; Electrical Connection - Rangemaster PROP90NGF User's Manual & Installation Instructions

Classic, kitchener and professional + 90 gas
Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have finished.
Fig. 10.14
Earth: to the
terminal marked E,
coloured Green/Yellow
Neutral: to the
terminal marked N,
coloured Blue
INSTALLATION

Pressure Testing

The gas pressure can be measured at one of the hotplate
burner injectors (not the wok burner).
Lift off a burner head. Fit the pressure gauge to the injector.
Turn on and light one of the other hotplate burners.
Turn on the control knob for the burner with the pressure
Live: to the
gauge fitted to let gas through.
terminal marked L,
See the data badge for test pressures.
coloured Brown
Turn off the burners. Make sure that you reassemble the
burner top in the correct way on the burner body.

Electrical Connection

The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
n
All external wiring must comply with the IEE Regulations
for the Electrical Equipment of Buildings. Connection to the
electrical supply can be made with either a plug and socket
or be permanently wired via a double-pole switch. The cooker
is supplied with a 3-core cable 2 m long. If a replacement
cable is fitted it must be 250 V high temperature PVC (85 °C),
1 mm².
Should the plug not fit the socket in your home, it should be
removed and replaced with a suitable plug.
Note: If the plug is fitted is not suitable, it must be cut off and
disposed of properly. To avoid the risk of electrocution, the
plug must not be left where children might find it and plug it
into a supply socket.
Three pin plugs to BS 1363 with a capacity of not less than
13 A must be used and fitted with a 13 amp fuse 'ASTA'
approved to BS 1362.
You must refit the cover after replacing the fuse. If the cover is
lost, the plug must not be used until a replacement cover has
been obtained from your supplier. The colour of the correct
fuse carrier is that of the coloured insert in the base of the
fuse recess, or stated elsewhere on the plug. Always state this
colour when ordering a replacement fuse carrier.
IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code (Fig. 10.14):
33
WARNING: THIS APPLIANCE MUST BE EARTHED.
• Green and yellow: EARTH
• Blue:
NEUTRAL
• Brown:
LIVE