Installing The Grounding Cable; Dismantling - Siemens SIWAREX WL270 Operating Instructions Manual

Mounting plates cp-s sa
Table of Contents

Advertisement

Installation

5.3 Installing the grounding cable

5.3
Installing the grounding cable
1. Prepare a permanently contacting bolted connection such as M10 on the load bearing
2. Screw the grounding cable tight.
5.4

Dismantling

For the disassembly of load cells, the same safety rules and requirements apply as for
installation and assembly.
1. Disconnect all the supply voltages and auxiliary voltages.
2. Secure the load carrier against falling.
3. Use appropriate hoisting gear and tools.
4. Take the load off the load cell.
5. Carefully remove the load cell without using force. Do not pull on the cable of the load
6. Do not cut the cable if the load cell is to be re-used or sent in for repair.
7. Do not carry the load cell by the cable.
26
implement and foundation for securing the grounding cable.
cell.
Operating Instructions, 04/2009, A5E02522341B
CP-S SA