Wall Mounting the Drapery Track
1 1
1.1
Mount the brackets using the spacing illustrated below.
Mount the drapery track to the wall using the wall mount L brackets. Mount each end bracket at a
maximum dimension of between five (5) and six (6) inches from each end of the track. Space the next
bracket on both sides 16 in from the end brackets. Space the remaining brackets 16-24 in apart.
Note: All screws must be securely fastened to stud or structural member.
Top View
5-6
16 in
in
1.2
Install the track to the brackets using the cam locks.
The drapery track must be straight and level to operate properly. When the wall brackets are securely
mounted, install the track to the brackets using the cam locks. (SEE ILLUSTRATIONS BELOW FOR CAM
LOCK OPERATION)
Brackets MUST be mounted STRAIGHT AND LEVEL
SIVOIA QED
Drapery Installation Instructions
TM
Window/Wall Side
16-24 in
Side Elevation View
2
16-24 in
16 in
5-6
in
Level
Line