Your best resource for more
You can also visit our website
information is your doctor.
www.EDTreatments.com
Your doctor is most familiar with
your medical situation and can
work with you to make sure you
get the best possible results from
the penile implant.
1. AMS 700
™
with MS Pump
™
Series Patient Manual. Information and Instructions
for Patients Considering an Inflatable Penile Prosthesis. American Medical Systems,
Inc. 2019.
2. AMS 700 Penile Prosthesis with MS Pump Operating Room Manual.
American Medical Systems, Inc. 2018.
All cited trademarks are the property of their respective owners.
CAUTION: The law restricts these devices to sale by or on the order of a
physician. Indications, contraindications, warnings and instructions for use can
be found in the product labelling supplied with each device. Products shown
for INFORMATION purposes only and may not be approved or for sale in certain
countries. This material not intended for use in France.
Product available in the European Economic Area (EEA) only.
Please check availability with your local sales representative or customer service.
All images are the property of Boston Scientific. All trademarks are the property
of their respective owners.
MH-1085801-AA. Produced by Gosling.
How to Use Your Implant
www.bostonscientific.eu
2022 Copyright © Boston Scientific
AMS 700
INFLATABLE PENILE IMPLANT SERIES
Corporation or its affiliates.
™
All rights reserved.
DINURO2483EA
Need help?
Do you have a question about the AMS 700 and is the answer not in the manual?
Questions and answers
We seem to get the **** pumped to about 80% fullness. How can we get it completely full?
To fill the Boston Scientific AMS 700 to full capacity:
1. Fill a 60cc syringe with 40cc of sterile normal saline.
2. Attach a 15-gauge blunt needle from the accessory kit.
3. Hold the reservoir in your non-dominant hand and squeeze out as much air as possible.
4. While keeping the reservoir compressed, insert the needle into the tubing.
5. Aspirate all air from the reservoir using the partially filled syringe.
6. Inject 20–30cc of sterile normal saline without introducing air bubbles.
7. Press the side of the reservoir with your thumb to form a bowl shape.
8. Aspirate remaining saline and air until the syringe plunger meets resistance or the reservoir forms a flattened ball shape.
9. Leave the reservoir in the flattened ball shape.
10. Maintain upright pressure on the syringe plunger.
11. Clamp the reservoir tubing about one inch below the needle using a blue-shod mosquito hemostat, engaging only one notch.