Installation Procedures - Schwank ECOSCHWANK-MILLIVOLT Installation & Owner's Manual

Gas fired infra red heaters
Hide thumbs Also See for ECOSCHWANK-MILLIVOLT:
Table of Contents

Advertisement

3. INSTALLATION PROCEDURES

A. Properly install gas line as outlined in section
2.7, page 3.
B. Properly connect the ignition control assembly
to the heater.
C. Mount heaters by using non-combustible
mounting hardware as illustrated in Diagrams
2 on page 8. Observe the minimum clearances
as outlined in sections 9.3 to 9.6.
D. Connect heater to the main gas line. It is rec-
ommended to use a 1/2" flexible connector to
absorb gas line expansion and any
WARNING:
When testing the main gas line pressure, ensure the gas shut-off valve is
"OFF", otherwise damage to the combination gas valve will result.
building vibration (available as option from
Schwank Inc.)
E. Mount thermostat at desired location, away
from direct infra-red rays of heater and not on
cold wall without sufficient insulation back-
ing. Install exhaust fan, air switch and trans-
former, as per section 2.6, page 3.
F. Check gas line for leakage by using soap test
or gas meter test. Ensure gas pressure meets
the requirements outlined in section 2.8, page
3.
Page 4
SP-MECM-BX-05A
ecoSchwank - Millivolt Manual
RD: MAY, 2004
RL: 5