  • Page 1 Schwank Installation Manual Epic14 Series Air Curtain...
  • Page 2: General Instructions

    Application area hidden utilities. ■ Power sources should always be disconnected, Schwank Epic14 Series Air Curtain is designed to locked and tagged before being instgalled or create an environmental separation in any door serviced. opening that is between 3 feet and 10 feet wide, by ■...
  • Page 3: Operation

    Operation ■ 480V3~/ 600V3~ Control supply is transformed The unit must extend or overlap to the entire width of via external transformer to 208V~ and routed the door opening to create the most effective seal. to the Air Curtain The unit’s door opening is shielded, and heat loss is reduced by air being pulled in through the air 208V3~ Control supply is connected internally ■...
  • Page 4: Maintenance

    Maintenance Fan replacement All units 1. Determine which of the fans is not functioning. Since fan motors and other components are 2. Disconnect the cables from the relevant motor maintenance-free, no maintenance other than on the fan deck. cleaning is necessary. The level of cleaning can vary 3.
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Problems Possible Causes Solutions Non-Operational No Power from Power Source Ensure power line is active and ON Failed Switch Replace Failed Switch Blown Fuse Determine Root Cause then replace fuse Motor Safety Tripped Built-in motor safety switch, will reset automatically after cool down. Replace motor if it does not reset.
  • Page 6 Configurating The Epic Air Curtain Epic Air Curtain provides the flexibility with various features and customizable options available that makes it easy to install in field without any modifications or extra modules: Customize your air curtain in 2 Easy Steps:  1.
  • Page 7: Technical Specification

    Technical Specification Ambient, no heat Model Width Avg. Outlet Velocity Volume Total # of Motor (FPM) (inch) (CFM) Motors (HP) AC-EA036-20 3288 2368 AC-EA042-20 3221 2763 AC-EA048-20 3229 3157 AC-EA060-20 3241 3947 AC-EA072-20 3210 4736 AC-EA084-20 3221 5525 AC-EA096-20 3229 6315 AC-EA108-20 3288...
  • Page 8 Dimensions A/B/C/D E/F/G/H Inch Heated Model Ambient Model Inch Heated Model Ambient Model 37.12 AC-EE036-XX AC-EA036-20 122.24 AC-EE120-XX AC-EA120-20 43.12 AC-EE042-XX AC-EA042-20 21.50 All Models All Models 49.12 AC-EE048-XX AC-EA048-20 19.94 All Models All Models 61.12 AC-EE060-XX AC-EA060-20 8.00 All Models All Models 74.24 AC-EE072-XX...
  • Page 9 All Models: 36” - 60” All Models: 72” - 96” & 120” schwankgroup.com/schwankair...
  • Page 10 All Models: 180” Inch Heated Model Ambient Model AC-EE036-XX AC-EE036-XX 36.12 AC-EE072-XX AC-EE072-XX AC-EE108-XX AC-EE108-XX AC-EE042-XX AC-EE042-XX 42.12 AC-EE084-XX AC-EE084-XX AC-EE048-XX AC-EE048-XX 48.12 AC-EE096-XX AC-EE096-XX AC-EE060-XX AC-EE060-XX 60.12 AC-EE120-XX AC-EE120-XX AC-EE036-XX AC-EE036-XX 36.62 AC-EE072-XX AC-EE072-XX AC-EE042-XX AC-EE042-XX 42.62 AC-EE084-XX AC-EE084-XX AC-EE048-XX AC-EE048-XX 48.62...
  • Page 11: Mounting Kits

    Mounting Kits Angled Bracket Product Type Quantity Kit Model included Angled AC-0950-060 AC-EA036-20, AC-EA042-20, AC-EA048-20, AC-EA060-20, Bracket Kit AC-EE036-XX, AC-EE042-XX, AC-EE048-XX, AC-EE060-XX AC-0950-120 AC-EA072-20, AC-EA084-20, AC-EA096-20, AC-EA120-20, AC-EE072-XX, AC-EE084-XX, AC-EE096-XX, AC-EE120-XX AC-0950-108 AC-EA108-20,  AC-EE108-XX Note: When using an angled bracket with threaded rods and struts for all product types use the angled bracket kit model: ...
  • Page 12: Mounting And Installation

    Mounting and Installation Threaded Rods – Ceiling Mount Eight (Twelve for 108” unit) 3/8-16 threaded inserts are present on the top of the air curtain to attach the threaded rods at one end. The threaded rods opposite ends can be fastened to the ceiling.
  • Page 13 Concealed Backplate Wall Mount Kit The wall mount consists of two pieces, a plate that extends the whole length of the air curtain and a bracket that attaches to the air curtain. The back side of the plate has six mounting holes capable of accepting six 3/8 mounting bolts with washers.
  • Page 14 Accessories Accessories Description JC-0216-CC Plunger type Overhead Door Switch For Air Curtains (UL and CSA Certified) JC-0216-MM Roller Type Overhead Door Switch for Air Curtains (UL and CSA Certified) JC-0216-KT Heavy Duty Magnetic industrial Door Switch for Air Curtain with Actuator Kit JC-0209-HOA Epic14 Air Curtain HOA (Hands OFF AUTO) Switch With Enclosure JC-0209-XX...
  • Page 15 Controls and Activation Default Controls Package Features included with Default controls are as follows: Air Curtain Activation (ON/OFF) via optional Door Switch, optional disconnect switch, or hands-off auto switch. Time Delay: Ambient – The blowers will run until the door switch is open.
  • Page 16 Controls and Activation Advanced Controls Package The optional advanced control package offers enhanced features and functionality for the Epic14 Air Curtain series to our customers. The unit can be fully customized to individual needs or left in auto to provide the most optimized energy savings, with fully automized controls over air curtain features.
  • Page 17 Controls and Activation Advanced Control Package ■ Manual Time Delay – The user can input manual time delay in seconds. The air curtain will run for Features and Sequences Auto mode: the specified time after the door switch is closed. It will ignore the Intelligent traffic monitoring ■...
  • Page 18 With Schwank Epic Series, it is now possible to get aesthetics package with your industrial air curtain. The package includes a decorative front grill with a variety of colors to select from.  ...
  • Page 19 Optional Filters Optional Aluminum Washable Filters are available with Schwank Epic Series Air Curtain. These filters are included inside the air curtain packaging and are east to install and maintain. One of the main benefits of aluminum washable filters is that they can be easily cleaned and reused. To clean an aluminum washable filter, you simply need to remove it from the air curtain unit by unscrewing the front or top intake cover and rinse it off with water.
  • Page 20: Replacement Parts List

    Replacement Parts List Schwank Epic14 Series Air Curtain - Ambient schwankgroup.com/schwankair...
  • Page 21 Item Description Part # Notes Model # Front Shield, 36” JC-0871-36 AC-EA036-20, AC-EA072-20, AC-EA108-20 Front Shield, 37” JC-0871-37 108” Middle Front Shield AC-EA108-20 Front Shield, 42” JC-0871-42 AC-EA042-20, AC-EA084-20 Front Shield, 48” JC-0871-48 AC-EA048-20, AC-EA096-20 Front Shield, 60” JC-0871-60 AC-EA060-20, AC-EA120-20 Front Cover (NO INTAKE HOLES), 36”...
  • Page 22 Replacement Parts List Schwank Epic14 Series Air Curtain - Electric-Heated schwankgroup.com/schwankair...
  • Page 23 Item Description Part # Notes Model # Front Shield, 36” JC-0871-36 AAC-EE036-XX, AC-EE072-XX, AC-EE108-XX Front Shield, 37” JC-0871-37 108” Middle Front Shield AC-EE108-20 Front Shield, 42” JC-0871-42 AC-EE042-XX, AC-EE084-XX Front Shield, 48” JC-0871-48 AC-EE048-XX, AC-EE096-XX Front Shield, 60” JC-0871-60 AC-EE060-XX, AC-EE120-XX Front Cover (NO INTAKE HOLES), 36”...
  • Page 24 Item Description Part # Notes Model # Midget Fuse Block of One JC-0832-WW AC-EE108-XX, AC-EE120-XX Fuse Block of Two (60A) JC-0833-WW AC-EE108-XX, AC-EE120-XX Fuse Power Distribution Block-150A JC-0805-MM AC-EE036-XX, AC-EE042-XX, AC-EE048-XX, AC-EE060-XX, AC-EE072-XX, AC-EE084-XX, AC-EE096-XX Power Distribution Block-175A JC-0805-XX AC-EE108-XX, AC-EE120-XX Fuse Fuse Block of Three (60A) JC-0833-WW...
  • Page 25 ■ Read the safety instructions before performing installation and/or maintenance activities on the unit. ■ Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. ■ The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
  • Page 26 1-877-686-3779 (toll-free) 1-706-554-6191 csr@schwankgroup.com schwankgroup.com/schwankair Canada 2 Schwank Way, 5285 Bradco Blvd., Waynesboro, GA Mississauga, ON 30830 L4W 2A6 schwankgroup.com/schwankair...