Lift and remove the access panel.
3.
Turn the access panel over to locate the HP Moonshot 1500 Chassis label. This label provides information on
LED status indicators, component identification, and cartridge and switch installation procedures.
Remove the cartridge blank
CAUTION:
in each cartridge slot in the chassis. When replacing a cartridge, leave the cartridge slot empty
for no more than 30 seconds. Failure to do so can disrupt airflow in the chassis.
To remove the component:
Extend the chassis from the rack (on page 10).
1.
Remove the access panel (on page 11).
2.
Remove the cartridge blank from the chassis.
3.
Remove the cartridge
For proper cooling, be sure that a cartridge or a cartridge blank is always installed
Operations 12