Troubleshooting; Information Items And Diagnostic Codes - Samsung DV6000R Service Manual

Clothes dryer
Table of Contents

Advertisement

4. TROUBLESHOOTING

4-1. INFORMATION ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays.
Error Display
tC
The Thermistor 1 resistance is very low or high.
tC5
The Thermistor 2 resistance is very low or high.
dC
The dryer is running with thedoor open.
dF
Incorrect door switch.
bC2
Incorrect button state.
FC
Invalid power source frequency.
9C1
Electronic control problem (Invalid Voltage).
AC
Electronic control problem (Invalid Communication).
HC
Invalid heating Temp in runningthe dryer.
3C
Motor Relay short problem
■ Error Recall
Error Recall mode reminds users of the last error that was detected.
To Enter Error Recall mode Press and hold the model-specific buttons for 8 seconds as specified below.
In Error Recall mode, the last error that was detected appears. If no error has been found, nothing is displayed.
Trigger
DVE(G)45T6200*/6000*/6005* :
Dryness + Wrinkle Prevent
Action Taken
• Check for a clogged lint screen.
• Check if the vent system is restricted.
• Check the thermistor resistance.
• Check for a clogged lint screen.
• Check if the vent system is restricted.
• Check the thermistor resistance.
• Close the door, and run the dryer again.
• Check if the door sensor unit is loose or short.
• Check if the door sensor unit is loose or short.
• Check if the display PCB is loose or short.
• Check if you are using regular power source frequencies.
• Check the power frequency sensor circuit.
• Check the PCB and wire harness.
• Check if power is supplied properly.
• First check the PCB and wire harness.
• Replace the PCB if the problem persists.
• Check the PCB and Thermistor.
• Check the PBA.
.
Troubleshooting _ 23