Commissioning Instructions - Kinetico Premier Compact Installation And User Manual

Hide thumbs Also See for Premier Compact:
Table of Contents

Advertisement

Available languages

Available languages

Commissioning instructions

1
Pressurise:
With the water to the property restored, slowly move the assembly to the "in
service" position. Water may run to drain until the unit is fully pressurised.
2
Fill the brine tank
with water:
Allow the brine tank to fill with
water until the brine valve shuts off.
The water level should be
approximately 25mm over the
grid plate.
TIP:
If the cabinet does not fill
with water please refer to the
"Useful Information" section
(page 15).
Water level
Original Version
Grid plate
3
Initiate a backwash:
a:
Using a Phillips head screwdriver
push down on the actuator, and
slowly turn CLOCKWISE until the
indicator dot reaches the letter
W in the word "BACKWASH" on
the clear cap.
b:
You will hear a rush of water and
air going to the drain.
c:
When the cycle has finished
(approx 4 mins), repeat the
procedure, turn the indicator dot
to the next backwash cycle and
allow to finish (approx 4 mins).
Actuator
Indicator
13
www.kinetico.eu