Keypad Configuration - Essex Electronics K1 Series Installation Instructions Manual

Multi-format keypad reader
Hide thumbs Also See for K1 Series:
Table of Contents

Advertisement

Keypad Configuration

Voltage Selection
The factory default setting for the Keypad voltage is 12-24VDC.
Verify that the jumper is removed or placed over only one pin. For
5VDC, the jumper should be placed across both pins. If changing
the voltage is necessary, make sure the power is removed first.
Keypad Output Selection
Once the voltage jumper is verified or correctly set:
1. Remove power.
2. Jumper the two pins above the connector labeled "CONFIG."
3. Apply appropriate power. (You should hear 4 beeps and the
RED LED will flash and the GREEN LED will be solid.)
4. Now that the Keypad is in configuration mode, select the de-
sired output by entering the configuration number followed by #.
a. Keypad Output
Keypad Output
26 Bit Wiegand (default)
8 Bit Word
BCD
Serial ASCII
ABA Track II Clock & Data
4 Bit Word
Self-contained- ERM-3*
Self-contained- Non-encoded
*Requires Essex Encoded Relay Module. Refer to the manual for
the "K1-ERM Encoded Keyless Entry® Access Control System."
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Configuration Site Code
1 #
000
2 #
3 #
4 #
5 #
6 #
98 #
99 #
3