b. To change the audible beep, enter
Code
201 #
200 #
c.
To change the illumination on the K1-26 only, enter the
code as follows:
Code
210 #
211 #
212 #
213 #
214 #
You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will be
solid). If you hear a long error beep, re-enter the configuration
number followed by #.
5. Remove power.
6. Remove configuration jumper.
7. Re-apply power.
8. RED LED on, GREEN LED off.
IMPORTANT: Once the configuration is selected, you must re-
move power, remove the configuration jumper and then re-apply
power in order to complete the configuration procedure. Note: If
the configuration jumper is not removed, the LED's will flash and
the Keypad will beep continuously.
4
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Audible Beep
Normal Beep (factory default)
Short Click (quieter)
Standby Mode
Off (factory default) Off (factory default)
Off
Off
Dim
Dim
Normal Operation
Dim
Bright
Dim
Bright