a. Keypad Output cont'd.
Keypad Output
Self-contained- ERM-3*
Self-contained- Non-encoded
*Requires Essex Encoded Relay Module, which contains a serial
interface to connect a computer for programming and reading
codes, or a printer for real-time print-out of activities. Refer to the
manual for the "K1-ERM Encoded Keyless Entry® Access Control
System."
b. To change the audible beep, enter
Code
201 #
200 #
c.
To change the illumination on the K1-26 only, enter the
code as follows:
Code
210 #
211 #
212 #
213 #
214 #
You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will be
solid). If you hear a long error beep, re-enter the configuration
number followed by #.
7. Remove power.
8. Remove configuration jumper.
9. Re-apply power.
10. RED LED on, GREEN LED off.
6
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
Audible Beep
Normal Beep (factory default)
Short Click (quieter)
Standby Mode
Off (factory default) Off (factory default)
Off
Off
Dim
Dim
Configuration Site Code
98 #
99 #
Normal Operation
Dim
Bright
Dim
Bright

Hide quick links: