Melt:
If using a solid shortening this feature will cycle the heating
element on and off until it reaches a set temperature and is
completely melted. This eliminates air pockets around the element
which could cause excessive temperatures at exposed sections of
the heating element.
To turn the Melt Cycle On:
At the system programming screen press 3 to enter Parameters.
You will be prompted to enter a password. Press 2,2,2 and then
START
The system parameter screen will be displayed. Press 1 for
Temperature Parameters. Press 6 to enter the Melt / Boil
Parameters. The melt cycle is defaulted to OFF. Press 1 and then
any key to turn it from NO to YES. Press START to save the change.
Press POWER several times until the display goes blank.
Melt Cycle Parameters:
1. Melt Enabled
2. Melted At
3. Heat On
4. Heat Off
Boil Out:
The Boil Out cycle will boil water for a set amount of time and then shut off automatically. Adding a
cleaning agent such as Boil Out Pucks will improve the effectiveness.
To Start the Boil Out Cycle:
With the AutoFry turned off press and release the START button, then within two
seconds press the POWER button.
To Cancel:
Press CLEAR
Boil Out Parameters:
5. Boil Temp.
6. Boil Time
MTI-40E OM 02/17 Rev B
AutoFry
MTI-40E Operator's Manual
Yes / No
150°F (adjustable from 100 – 300°F)
7 (adjustable from 1 – 10 Seconds)
8 (adjustable from 5 – 30 Seconds)
195°F (adjustable from 190 – 212°F)
15:00 (adjustable from 5:00 – 25:00 minutes)
15
63-0009B