8. MAINTENANCE AND CLEANING

Normally, purging the valve with appropriate flush material or solvent after use is sufficient for
cleaning. However some material may cause a buildup in the valve chamber, in this case periodic and
thorough cleaning will be required.
CAUTION: Make sure the fluid pressure is released before disassemble the valve.

8.1 Cleaning

Refer to figure 6.0
1. Release fluid pressure
2. Disconnect fluid line
3. Disconnect valve air line
4. Remove the two socket head cap screws (1) from the fluid housing (2)
5. Pull the fluid housing away from the air cylinder assembly (10)
6. Clean Diaphragm (3) and fluid housing (2)
NOTE: Avoid using sharp probes for cleaning. Any nicks or scratches on the diaphragm
or the sealing area of the fluid housing may cause leakage.
7. Reinstall the fluid housing (2).
8. Align the fluid housing mounting holes with diaphragm and air cylinder holes.
9. Reinsert the two socket head cap screws (1). Tighten in accordance with the Torque
specifications Chart below.