IFM DTI420 Operating Instructions Manual page 21

Rf-identification system
Table of Contents

Advertisement

u Use the control to set the following values in the process data output: the command value "0x03",
the address (16 bits) and the data length (16 bits).
u With the control, start the read operation with the status bit "Cmd Start".
w The device acknowledges the start of the read operation by setting the status bit "Cmd Start
Acknowledge" in the process data input.
w The device transfers the data in the process data input (data 0 to 27) and increases the block
counter by 1 as soon as the first data of the ID tag is available. The block counter is reset to "0"
when the value exceeds "255".
u With the control, acknowledge the receipt of the data by increasing the block counter in the process
data output by "1".
u The last two steps are repeated until all data has been transferred.
w The device sets the status bit "Cmd End" with the last transfer.
The read operation is terminated.
If reading was unsuccessful, the device sets the error value and the status bit "Cmd End" in the
process image. The data transmission is interrupted.
Byte
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Process data output
Command value = 0x03
Status
ignored
ignored
Address (high byte)
Address (low byte)
Length (high byte)
Length (low byte)
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
ignored
DTI420 DTI421
Process data input
Command value = 0x03
Status
Data 0
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Data 9
Data 10
Data 11
Data 12
Data 13
Data 14
Data 15
Data 16
Data 17
Data 18
Data 19
Data 20
Data 21
Data 22
Data 23
Data 24
Data 25
21