KROHNE OPTIWAVE 1010 Supplementary Instructions Manual

KROHNE OPTIWAVE 1010 Supplementary Instructions Manual

Radar (fmcw) level transmitter for bypass chambers and magnetic level indicators (bm 26 advanced)
Hide thumbs Also See for OPTIWAVE 1010:

Advertisement

Quick Links

OPTIWAVE 1010
OPTIWAVE 1010
OPTIWAVE 1010
OPTIWAVE 1010
Radar (FMCW) Level Transmitter for bypass chambers
and magnetic level indicators (BM 26 Advanced)
Supplementary Instructions for ATEX applications
Supplementary Instructions for ATEX applications
Supplementary Instructions for ATEX applications
Supplementary Instructions for ATEX applications
© KROHNE 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en
Supplementary instructions
Supplementary instructions
Supplementary instructions
Supplementary instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTIWAVE 1010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KROHNE OPTIWAVE 1010

  • Page 1 Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Supplementary Instructions for ATEX applications Supplementary Instructions for ATEX applications Supplementary Instructions for ATEX applications Supplementary Instructions for ATEX applications © KROHNE 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 2: Table Of Contents

    5.3 How to remove the device ....................19 5.4 Manufacturer ........................19 5.5 Returning the device to the manufacturer..............20 5.5.1 General information......................20 5.5.2 Form (for copying) to accompany a returned device............21 www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 3 CONTENTS OPTIWAVE 1010 6 Notes 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 4: General Safety Information

    31:2014. The Ex ia, Ex db and Ex tb versions are certified for use in hazardous areas by the Kiwa ExVision B.V. under the EC-Type Examination Certificate KIWA 15ATEX0022 X. WARNING! Carefully read the ATEX approval certificate. Obey the boundary conditions. www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 5: Device Categories

    Category 2 D (dust) and EPL Db equipment when fitted with the appropriate options. The surface temperature of the device (without a layer of dust) cannot be more than +120°C / +248°F. Category 2 D equipment is used in zone 21. 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 6: Atex Nameplates

    5 Input voltage range and maximum current (4...20 mA passive – HART) 6 Degree of ingress protection (if fitted with the appropriate cable glands) 7 Type code (defined in the "order code" section of the technical data sheet) www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 7: Installation

    • you can get access to the device, • there is sufficient space around the device for inspections • you can see the device nameplate, and • there are no external forces applied on the device. 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 8: Electrostatic Discharge

    • locations near other machines and systems that can have large electrostatic charges. Figure 2-1: ESD warning sticker (below the device nameplate) 1 Text: Warning 2 Text: Potential electrostatic charging hazard – see instructions www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 9: Operating Conditions

    • Aluminium = the device with the aluminium housing option • HT = high-temperature version of the device with the aluminium housing option • Stainless steel = the device with the stainless steel housing option 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 10 +150 +302 +100 +212 +100 +212 +140 +100 +212 +150 +302 +194 +194 +158 1 Use heat-resistant cables and cable glands certified for continuous operation above +90°C / +194°F www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 11: Electrical Connections

    How to open the Ex d / Ex t terminal compartment Figure 3-2: How to open the Ex d / Ex t terminal compartment 1 Cover stop 2 Terminal compartment cover 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 12: How To Close The Terminal Compartment

    • Make sure that the cover stop 1 screw is tight. 3.3 Terminal tightening capacity The terminal tightening capacity for the current output terminals is: Type of wire Terminal tightening capacity [mm²] [AWG] Rigid Flexible www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 13: Equipotential Bonding System

    (Tamb = -40...+100°C / -40...+212°F). Make sure that the seals are tight. • Connect only to separate certified, intrinsically-safe circuits. Make sure that the electrical circuit characteristics are not more than the values that follow. 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 14: Maximum Intrinsically-Safe Values For The Electrical Circuit

    "ib. If the device is connected to an intrinsically-safe circuit with protection concept "ia", the device operates with a higher level of safety. www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 15: Ex Db / Ex Tb Equipment

    3.6.2 Supply voltage Minimum voltage at Maximum voltage at output terminals [VDC] output terminals [VDC] Current output terminals 14.5 1 For a current output of 22 mA 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 16: Electrical Schematic

    Figure 3-5: Electrical schematic for Ex db / Ex tb-approved equipment 1 Power supply 2 Resistor for HART® communication 3 Non-Ex zone 4 Ex zone 5 Grounding wire –if the electrical cable is shielded (braided wire etc.) www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 17: Start-Up

    • Did you install the correct cable entries? Is the terminal compartment correctly sealed? • Make sure that the installation and wiring agree with local regulations. WARNING! Use the device only in the specified measuring range. 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 18: Service

    (external thread tolerance class: 6g), are made of A4-70 stainless steel, and agree with International Standard ISO 4762. 5.2 How to clean the device DANGER! If dirt collects on the device, clean it with a damp cloth. www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 19: How To Remove The Device

    KROHNE S.A.S. 2 Allée des Ors – B.P. 98 26103 Romans-sure-Isère CEDEX France If you need to return your device for inspection or repair, obey the instructions that follow. 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 20: Returning The Device To The Manufacturer

    • such dangerous substances, to enclose a certificate with the device confirming that is safe to handle and stating the • product used. www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 21: Form (For Copying) To Accompany A Returned Device

    We have flushed out and neutralized all cavities in the device. We hereby confirm that there is no risk to persons or the environment through any residual media contained in the device when it is returned. Date: Signature: Stamp: 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 22 NOTES OPTIWAVE 1010 www.krohne.com 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en...
  • Page 23 NOTES OPTIWAVE 1010 09/2015 - 4004191901 - AD ATEX OPTIWAVE 1010 R01 en www.krohne.com...
  • Page 24 • Process Analysis • Services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: www.krohne.com...

Table of Contents