Wall luminaires surface mounted

Advertisement

5) Feed mains supply cable G (and second cable
H for through wiring, if required) through cable
entry J, while setting wall flange A in position.
I
J
A
G
H
6) To fix the wall flange A, insert and tighten screws
E. When aligning the flange plate, observe the
sticker „light direction". The screws E are not
included in delivery.
The pre-assembled cable entry J and packing ring I
are suitable for cable diameters of 0.276 – 0.374 in.
For larger cable diameters of 0.354 – 0.472 the en-
closed cable entries must be used.
A
E
7) Connect leads of main supply cable H (and
second cable I for through wiring, if required)
to respective terminals of socket K:
a) ON/OFF (L = Phase,
= Earthing,
N = Neutral,
ON/OFF
K
G
8) Position luminaire housing B over wall flange A
and reconnect terminal connector D. Place the
luminaire housing B over wall flange A and
tighten two screws C gradually, in alternating
sequence, both on top and bottom until fully
secured.
b) 0-10 V (L = Phase, N = Neutral,
= Earthing, D–/D+ = 0-10 V control line)
0-10 V
K
G
A
D
A
C
B