Download Print this page

WE-EF RLS400 LED Series Installation And Maintenance Instructions page 2

Wall luminaires surface mounted

Advertisement

Wall Luminaires surface mounted
IP66, IK08
5.91 7.09
7.09
ø 0.236
3.94
3.94
RLS410
Light Source
RLS410 . . . . . . . . . . . . . . . . . . 3 LED 6W/ 9W / 13W*
RLS420 . . . . . . . . . . . . . . . 6 LED 12W / 18W / 26W*
* Nominal power, for latest data refer to
www.we-ef.com
Tools required
– Screwdriver TX25
10.63
5.91
10.63
ø 0.236
3.94
3.94
3.94
RLS420
Class I, ta = 40 °C
ø 0.276 – 0.374 in
max. 14 AWG
(ø 0.354 – 0.472 in)
Installation
The product must be installed and maintained by
a suitably qualified professional in compliance with
latest building/construction and/or electrical regu-
lations and relevant legislation.
Notice: If the luminaire is modified by anybody
other than the original manufacturer, then the
warranty will no longer be valid and shall become
the full responsibility of the modifying person/
organisation. Claims based on defects attributable
to improper installation and/or application, and the
consequences thereof, are excluded.
In case of component failure, LED replacement
due to abnormal circumstances or at end of life,
replacement must be carried out by a suitably qua-
lified and trained professional.
In case of questions please contact our technical
hotline: +1 724 742 0030 (from Monday - Friday
from 08.00 until 16.00 hours).
Maintenance
Apart from cleaning the product's exterior surfaces,
no special maintenance work is required. Do not
use high-pressure cleaners.
Protect our environment: Discard used LEDs in
compliance with the most recent environmental
legislation.