Main Unit Adjustment - Pioneer PRO-1000HDI Service Manual

Hide thumbs Also See for PRO-1000HDI:
Table of Contents

Advertisement

1

7.3.2 MAIN UNIT ADJUSTMENT

Panel-White-Balance Adjustment
A
Input Signal
B
Mask-Level Adjustment
Adjusting Point
Input Signal
VIDEO OPTION mode in
Factory mode
SIDE MASK LEV.
R SIDE LEVEL : key 1
G SIDE LEVEL : key 2
B SIDE LEVEL : key 3
C
D
E
F
136
1
2
Adjusting Point
Adjust the OFFSET-DIGITAL parameters (from PANEL R-HIGH to PANEL B-LOW) in Factory
mode.
For adjustment, use the mask (MASK04) signal of Factory mode for display.
Reference : Adjustment values when using the Minolta color-difference meter (A-100)
x
y
Side mask color / Level Adjustment
Set the indicated value with the keys on the remote control unit (1, 2 and 3 keys).
2
3
Adjusting Method
MASK Left Side
MASK Right Side
295
291
306
300
Adjusting Method
PRO-1000HDI
3
4
4