8.7.3 LrFhssSetSyncWord

Command LrFhssSetSyncWord(...) sets the LR-FHSS Syncword

Table 8-25: LrFhssSetSyncWord Command

Byte
0
Data from Host
0x02
Data to Host
Stat1
Syncword: LR-FHSS Syncword. Default value is {0x2C, 0x0F, 0x79, 0x95}.

8.7.4 Circuit Configuration for Long Range FHSS Transmission

After power up (battery insertion or hard reset) the LR1121 runs automatically a calibration procedure and goes to
STDBY_RC mode. This is indicated by a low state on BUSY pin.
From STDBY_RC, the sequence of operations needed to transmit a Long Range FHSS packet are:
1. If not in STDBY_RC mode, then set the circuit in this mode with the command SetStandby(...).
2. Set the basic configuration parameters such as RF switch, PA configuration, OCP, TxParams, RfFrequency...
3. Define the modulation (LR-FHSS) with the command SetPacketType(...).
4. Set the modulation parameters (SetModulationParams(...) command) with the proper Bit Rate (488.28125 bps),
the proper Pulse Shape.
5. Call the command LrFhssBuildFrame(...).
6. Activate the IRQ: TxDone.
7. Set the circuit in transmitter mode to start transmission with the command SetTx(...).
8. Wait for TxDone interrupt.
If configured, LrFhssHop IRQ is asserted at each frequency hop inside the LR-FHSS packet, after each PA ramp-up.
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
1
2
0x2D
Syncword[0]
IrqStatus
Stat2
(31:24)
www.semtech.com
3
4
Syncword[1]
Syncword[2]
IrqStatus
IrqStatus
(23:16)
(15:8)
5
Syncword[3]
IrqStatus
(7:0)
82 of 130
Semtech
Proprietary & Confidential

Advertisement

Table of Contents
loading

Table of Contents