7.2.13 SetLoRaSyncWord
This command sets the SetLoRaSyncWord.
Table 7-16: SetLoRaSyncWord Command
Byte
Data from Host
Data to Host
•
Syncword: Sets the SetLoRaSyncWord. Valid for all SFs. Example values are:
0x12: Private Network (default).
0x34: Public Network.
7.2.14 GetLoRaRxHeaderInfos
Command GetLoRaRxHeaderInfos(...) returns the information coded in the last received packet header (explicit
header mode), or the configured coding_rate and crc_type settings:
Table 7-17: GetLoRaRxHeaderInfos Command
Byte
Data from Host
Data to Host
Table 7-18: GetLoRaRxHeaderInfos Response
Byte
Data from Host
Data to Host
•
Infos:
bits 7-5: 0 RFU
bits 4: 1= CRC ON, 0 = CRC OFF
bit 3: 0 RFU
bits 2-0: coding rate (see
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
0
0x02
Stat1
0
0x02
Stat1
0
0x00
Stat1
8.3.1 SetModulationParams
www.semtech.com
1
0x2B
Stat2
1
0x30
Stat2
1
0x00
Infos
command for values)
2
Syncword
IrqStatus (31:24)
58 of 130
Semtech
Proprietary & Confidential