7.2.3 SetTx

Command SetTx(...) sets the sub-GHz radio or the HF radio in TX mode, triggering RF packet transmission, and starting
the RTC with the given TxTimeout value. There is no PA selection based on the RfFreq configuration. For details on PA choice
and operation refer to
Section 9.
If the RTC event fires before the end of transmission, it triggers a TIMEOUT IRQ, and stops the transmission. Otherwise, at
the end of the packet transmission, a TX_DONE interrupt is generated.
After a TIMEOUT IRQ or TX_DONE IRQ, the device goes back to STBY_RC (default), STBY_XOSC or FS depending on the
FallBackMode configuration.

Table 7-3: SetTx Command

Byte
Data from Host
Data to Host
TxTimeout is expressed in periods of the 32.768kHz RTC. The maximum value corresponds to 512 s.
0x000000 disables the timeout function.
If no packet type was configured, or the packet type does not allow Tx operations, the command fails.
The BUSY signal goes to 0 after the device is set into TX mode.
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
0
1
0x02
0x0A
Stat1
Stat2
www.semtech.com
2
TxTimeout (23:16)
TxTimeout (15:8)
IrqStatus(31:24)
IrqStatus(23:16)
3
4
TxTimeout (7:0)
IrqStatus(15:8)
50 of 130
Semtech
Proprietary & Confidential