Power Distribution; Power Modes; Setregmode; Table 5-1: Setregmode Command - Semtech LR1121 User Manual

Table of Contents

Advertisement

5. Power Distribution

5.1 Power Modes

Two power modes are available:
DC-DC converter for low power applications,
LDO for low-cost or small size applications.

5.1.1 SetRegMode

Command SetRegMode(...) defines which regulator should be used.

Table 5-1: SetRegMode Command

Byte
Data from Host
Data to Host
RegMode defines if the DC-DC converter has to be switched ON:
0: Do not switch on the DC-DC converter in any mode (Default).
1: Automatically switch on the DC-DC converter, depending on the mode as per
Other values are RFU.
This command only works with the device in Standby RC mode, otherwise it returns CMD_FAIL on the next GetStatus
command.
The following table illustrates the power regulation options for different modes and user settings.

Table 5-2: Power Regulation Options

Circuit Mode
Regulator Type = 0
Regulator Type = 1
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
0
0x01
Stat1
Sleep
STDBY_RC
-
LDO
-
LDO
www.semtech.com
1
0x10
Stat2
STDBY_XOSC
FS
LDO
LDO
DC-DC + LDO
DC-DC + LDO
2
RegMode
IrqStatus (31:24)
Table
5-2.
RX
TX
LDO
LDO
DC-DC + LDO
DC-DC + LDO
Proprietary & Confidential