5. Power Distribution
5.1 Power Modes
Two power modes are available:
•
DC-DC converter for low power applications,
•
LDO for low-cost or small size applications.
5.1.1 SetRegMode
Command SetRegMode(...) defines which regulator should be used.
Table 5-1: SetRegMode Command
Byte
Data from Host
Data to Host
•
RegMode defines if the DC-DC converter has to be switched ON:
0: Do not switch on the DC-DC converter in any mode (Default).
1: Automatically switch on the DC-DC converter, depending on the mode as per
Other values are RFU.
This command only works with the device in Standby RC mode, otherwise it returns CMD_FAIL on the next GetStatus
command.
The following table illustrates the power regulation options for different modes and user settings.
Table 5-2: Power Regulation Options
Circuit Mode
Regulator Type = 0
Regulator Type = 1
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
0
0x01
Stat1
Sleep
STDBY_RC
-
LDO
-
LDO
www.semtech.com
1
0x10
Stat2
STDBY_XOSC
FS
LDO
LDO
DC-DC + LDO
DC-DC + LDO
2
RegMode
IrqStatus (31:24)
Table
5-2.
RX
TX
LDO
LDO
DC-DC + LDO
DC-DC + LDO
Proprietary & Confidential
41 of 130
Semtech