Setrxtxfallbackmode; Table 7-5: Setrxtxfallbackmode Command - Semtech LR1121 User Manual

Table of Contents

Advertisement

7.2.5 SetRxTxFallbackMode

Command SetRxTxFallbackMode(...) defines what mode the device goes into after a packet transmission or a packet
reception. If an Rx Duty Cycle is started or an AutoRxTx is configured, this mode is not used.

Table 7-5: SetRxTxFallbackMode Command

Byte
Data from Host
Data to Host
FallbackMode values:
0x01: Standby RC mode (default value).
0x02: Standby Xosc mode.
0x03: FS mode.
Other values are RFU.
The fallback mode is also used for an Rx Duty Cycle after the RX_DONE interrupt, or for an AutoRxTx after the RX to TX, or
when the TX to RX sequence is completed.
LR1121
User Manual
Rev 1.1
UM.LR1121.W.APP
Mar 2023
0
0x02
Stat1
www.semtech.com
1
0x13
Stat2
IrqStatus (31:24)
Proprietary & Confidential
2
FallbackMode
52 of 130
Semtech

Advertisement