Safety Warnings

CAUTION: See installation instructions before connecting the router. This is a
summary of safety warnings. For a complete list of warnings for this router, including
translations, see the IBM Ethernet Router J02M Hardware Guide at
http://www.elink.ibmlink.ibm.com/publications/servlet/pbi.wss
CAUTION: The intrabuilding port(s) of the router is suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intrabuilding port(s) of the
router MUST NOT be metallically connected to interfaces that connect to the OSP or
its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type
2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation from
the exposed OSP cabling. The addition of primary protectors is not sufficient
protection to connect these interfaces metallically to OSP wiring.
CAUTION: Before removing or installing components of a router, attach an ESD strap
to an ESD point and place the other end of the strap around your bare wrist. Failure
to use an ESD strap could result in damage to the router.
CAUTION: Use an external surge protective device (SPD) at the AC input of the router.
22
Safety Warnings
[edit]
root@host# exit
root@host>
Only trained and qualified personnel should install or replace the router. If you
need additional assistance installing the router, contact your IBM representative.
Perform only the procedures described in this quick start or the IBM Ethernet
Router J02M Hardware Guide. Other services should be performed by authorized
service personnel only.
Read the installation instructions before you connect the router to a power source.
Before installing the router, read the guidelines for site preparation in the IBM
Ethernet Router J02M Hardware Guide to make sure that the site meets power,
environmental, and clearance requirements for the router.
For the cooling system to function properly, the airflow around the chassis must
be unrestricted. Allow at least 6 in. (15.2 cm) of clearance between side-cooled
routers. Allow 2.8 in. (7 cm) between the side of the chassis and any
non-heat-producing surface such as a wall.
When installing the router, do not use a ramp inclined more than 10 degrees.
.