3. ELECTRICAL ADJUSTMENT

Calibration Procedures – PDR-M60
1.
Equipments
1) Light Box:
DNP Standard Color Viewer
Model: CCV51F
Use Lamp: FL-10W-4
Voltage : 100V
2) Vector Scope
3) Focus Test Charts
Supplied from TOSHIBA.
Near Focus Chart
Supplied as PDF file.
Far Focus: farchart1.pdf, farchart2.pdf
2
CCD Calibration
Tools:
Power Supply (Topward: DC Power Supply set to 5V)
DNP Light Box
Camera Positioning Fixture
Smart Media card with Calibration Code
Procedure:
1.
Install Smart Media card with Sierra Imaging Provided Calibration Code into camera.
2.
Place camera into the positioning fixture camera lens should be no more than 1 cm form the surface o
light box.
3.
Attach camera to power supply
4.
Turn on camera
* Calibration firmware version is shown on B/W LCD.